Menu
INDOOR UNITS
AIR COOLED
n
WATER COOLED
n
RESIDENTIAL
n
COMMERCIAL
n
RENOVATION
n
NEW CONSTRUCTION
VRV: The Components Condensing units
Air-Cooled Condensers
Water-Cooled Condenser
Heat Pump
Heat Pump or Heat Recovery
Heat Pump or Heat Recovery
3 and 4-Ton 208-230V/60Hz/1ph
6 to 16-Ton 208-230V60Hz/3ph or 460V/60Hz/3ph
6 to 21-Ton 208-230V/60Hz/3ph
REFNET® REFNET joints distribute an equal flow of refrigerant in every branch of the piping network.
A BSVQ changeover box is necessary for heat recovery applications.
Controls Individual Zone Controllers Navigation Wired R/C BRC1E71
Simplified Wired R/C BRC2A71
Wireless R/C BRC7C812 BRC7E83 BRC4C82 BRC7E818
®
LonWorks Networks Compatible Interface n Interface for LonWorks
A B SO L U T E C O MF O RT
2
networks n 0007Communication via LON protocol (twisted pair wire) n 64 units connectable per interface n Unlimited site size n Quick, easy installation
DAIKIN AC
Multi-Zone Controllers
Time Clock Controllers
Unified On/Off R/C DCS301C71
Schedule Timer DST301BA61
Centralized R/C DCS302C71
Integrated control system connecting VRV system with Building Management system n Interface for BMS system n Communication via BACnet®
protocol (BACnet/IP) n 256 units connectable per BACnet gateway (with DAM411B51) n Unlimited site size n Quick, easy installation ®
IMP-128/256/512/768/1,024
DCS601C71
n 1,024 indoor units (organized in
n 64 groups (128 indoor
n
n
n
n
up to 200 control groups) Management of AC units and ancillary equipment Operation on one master PC and one sub PC (sub PC option) Remote monitoring via the Web Alarm e-mail function
units) connectable
n Management of AC
units and ancillary equipment n Touch screen display n Built-in Ethernet port, Web enabled (optional) n Alarm e-mail function
VRV Indoor Units Capacity Range
Indoor Type
Page
MBH
7.5
09
12
18
24
30
36
42
48
54
72
96
Tons
0.6
0.75
1
1.5
2
2.5
3
3.5
4
4.5
6
8
OSA
OSA
OSA
OSA
OSA
OSA
OSA
OSA
FXTQ_PAVJU Vertical air handling unit (horizontal RHS is possible)
4
FXMQ_PVJU
Ducted
DC ducted concealed ceiling (medium static)
6 OSA
OSA
OSA
OSA
OSA
OSA
OSA
OSA
FXMQ_MVJU Concealed ceiling unit (medium static)
8 OSA
OSA
FXDQ_MVJU Slim duct built-in concealed ceiling unit
10 OSA
OSA
OSA
OSA
OSA
FXFQ_PVJU Round flow ceiling mounted cassette
12 OSA
OSA
OSA
OSA
OSA
OSA
OSA
FXZQ_M7VJU 2’ x 2’ 4-way ceiling mounted cassette
14 OSA
OSA
OSA
OSA
FXAQ_MVJU
Duct-free
Wall mounted unit
16
FXHQ_MVJU Ceiling suspended unit
18
FXLQ_MVJU Floor standing unit
20
FXNQ_MVJU Concealed floor standing unit
20 OSA
FXMQ_MFVJU 100% Outside Air Processing Unit
22 OSA
Available (11 types, 51 models) Condensate pump standard on model OSA
OSA
Outside air connection possible on model
OSA
OSA
A B SO L UT E C OM F O RT
Ventilation
OSA
INDOOR w w w. d a i k i n a c . c o m
3
Vertical Air Handling Unit FXTQ_PAVJU Concealed. Powerful. Compact. Comfortable. The upflow or horizontal (RHS) air handling unit is designed for use with all Daikin VRV® systems allowing more flexibility and combination possibilities. Ranging from 1 to 4 1/2 tons, the vertical air handling* unit by Daikin will take your next installation above and beyond your expectations. *Horizontal right configuration is possible
OSA
Outside air integration possible
Electric heater options Model Name FXTQ12PAVJU FXTQ18PAVJU FXTQ24PAVJU FXTQ30PAVJU FXTQ36PAVJU FXTQ42PAVJU FXTQ48PAVJU FXTQ54PAVJU
5kW
15kW
20kW
n
n
X
X
l
n
n
X
X
X
X
X
X
l
n
n
X
n
n
X
X
l
l
l
l
n
n
n
X
X
n
n
n
X
l
X
l
l
l
n
nu
X
l
l
l
l
n
nu
nu
l
l
l
l
n
nu
nu
l Electric heater operation with heat pump is allowed
X Not allowed
n Only electric heater operation is allowed
u Acceptable 2 step heating operation
The FXTQ_PAVJU represents an improvement in Electric Heater options and control logic versus previous units: n W 0007 ide line up of electric heat (field installed) options from 3kW to 20kW n 0007Integrated KRP1 function to minimize cost n 0007Electric heater operation in combination with heat pump operation (boost) is now possible n Reduced operational deadband A field supplied and installed Ground Fault Circuit Interrupter is required when utilizing the electric heat option
Features and Benefits
Application
n R 0007 educed installation time with integrated Electronic Expansion Valve and Printed Circuit Boards n 0007Improved application flexibility with the ability to mix and match with other Daikin indoor units on the same system n 0007Wider application range with dual voltage 208-230V/1ph/60Hz power supply n 0007Reduced piping cost with smaller piping diameters n 0007Only up flow and horizontal right installation is permitted n 0007Improved user comfort with 2 selectable fan speeds (H and L) n 0007New fan “Auto” logic allowing the unit to be commissioned where the fan operation will cycle on and off with the load n 0007The ECM fan motor as standard contributes to the increase in energy efficiency, reduction in sound and increased ESP (up to 0.5” W.G.) n 0007Ideal replacement for fan coils, vertical stacks or PTACs n 0007Replacement for geothermal heat pump and traditional split systems n 0007New construction or replacement
n n n n
A B SO L U T E C O MF O RT
4
Electrical heater capacity 6kW 8kW 10kW
3kW
DAIKIN AC
O 0007 ffices H 0007 otels M 0007 ulti-family residences S0007 ingle family residences
FXTQ Specifications FXTQ Specifications
1-Ton
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L External Static Pressure Range Unit Condensate Connection Gas Pipe Connections Liquid External Finish
V/ph/Hz Btu/h Btu/h
cfm lbs. in. in. in. dB(A) in. W.G. in. O.D. in. in.
Protection Devices Recommended Fuse/Breaker
A
1.5-Ton
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
2-Ton
2.5-Ton
3-Ton
3.5-Ton
4-Ton
4.5-Ton
FXTQ12PAVJU FXTQ18PAVJU FXTQ24PAVJU FXTQ30PAVJU FXTQ36PAVJU FXTQ42PAVJU FXTQ48PAVJU FXTQ54PAVJU 208-230/1/60 12,000 18,000 24,000 30,000 36,000 42,000 48,000 54,000 13,500 20,000 27,000 34,000 40,000 47,000 54,000 60,000 R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A Electronic Expansion Valve 400/280 600/420 800/560 1,000/700 1,200/840 1,400/980 1,600/1,120 1,800/1,260 119 119 145 145 145 167 167 167 46 3/4 46 3/4 53 1/4 53 1/4 53 1/4 53 1/4 53 1/4 53 1/4 19 1/2 19 1/2 22 22 22 22 22 22 22 22 24 24 24 24 24 24 n/a n/a n/a n/a n/a n/a n/a n/a up to 0.5 up to 0.5 up to 0.5 up to 0.5 up to 0.5 up to 0.5 up to 0.5 up to 0.5 3/4 (fpt) 3/4 (fpt) 3/4 (fpt) 3/4 (fpt) 3/4 (fpt) 3/4 (fpt) 3/4 (fpt) 3/4 (fpt) 1/2 (Braze) 1/2 (Braze) 5/8 (Braze) 5/8 (Braze) 5/8 (Braze) 5/8 (Braze) 5/8 (Braze) 5/8 (Braze) 1/4 (Braze) 1/4 (Braze) 3/8 (Braze) 3/8 (Braze) 3/8 (Braze) 3/8 (Braze) 3/8 (Braze) 3/8 (Braze) Fully insulated, painted steel cabinet with gray finish Fuse Fan Motor Thermal Protector 15 15 15 15 15 15 15 15 Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
Note: Specifications are subject to change without notice.
FXTQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor kit Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB
FXTQ12PAVJU FXTQ18PAVJU FXTQ24PAVJU FXTQ30PAVJU FXTQ36PAVJU FXTQ42PAVJU FXTQ48PAVJU FXTQ54PAVJU BRC1E71 BRC1E71 BRC1E71 BRC1E71 BRC1E71 BRC1E71 BRC1E71 BRC1E71 BRC2A71 BRC2A71 BRC2A71 BRC2A71 BRC2A71 BRC2A71 BRC2A71 BRC2A71 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 KRCS01-4B KRCS01-4B KRCS01-4B KRCS01-4B KRCS01-4B KRCS01-4B KRCS01-4B KRCS01-4B KRP1C75 1
KRP1C75 1
KRP4A74 2
(connects to external BMS)
KRP1C75 1
KRP4A74 2
KRP1C75 1
KRP4A74 2
KRP1C75 1
KRP4A74 2
KRP1C75 1
KRP4A74 2
KRP1C75 1
KRP4A74 2
KRP1C75 1
KRP4A74 2
KRP4A74 2
External Control Adapter for Outdoor Unit DTA104A53 DTA104A53 DTA104A53 DTA104A53 DTA104A53 DTA104A53 DTA104A53 DTA104A53 2 Fixing Box KRP1B101 3 KRP1B101 3 KRP1B101 3 KRP1B101 3 KRP1B101 3 KRP1B101 3 KRP1B101 3 KRP1B101 3 Air Filter FIL 36-42 FIL 36-42 FIL 48-61 FIL 48-61 FIL 48-61 FIL 48-61 FIL 48-61 FIL 48-61 Insulation Kit (vertical) DPI 36-42/20 DPI 36-42/20 DPI 48-61/-20 DPI 48-61/-20 DPI 48-61/-20 DPI 48-61/-20 DPI 48-61/-20 DPI 48-61/-20 Insulation Kit (horizontal) DPIH 36-42 DPIH 36-42 DPIH48-61 DPIH48-61 DPIH48-61 DPIH48-61 DPIH48-61 DPIH48-61 1 Need 24VAC power supply 2 Need 16VDC power supply 3 Fixing box installed beside the unit * Optional face plates available to provide a more intuitive user interface and disable specific functions 2
2
2
2
2
2
2
FXTQ Installation Space
12” or more
12” or more
24” or more Ceiling
(length: in.)
Ensure there is sufficient space under the unit (see H dimension) so that return-air ductwork can be installed and a downward slope of 1/100 can be maintained for drain piping.
H
A B SO L UT E C OM F O RT
12” or more
INDOOR w w w. d a i k i n a c . c o m
5
DC Ducted Concealed Ceiling Unit (medium static) FXMQ_PVJU Concealed. Quiet. Compact. Comfortable. For small to large well-populated spaces in need of a concealed air-conditioning system, you can count on our ceiling mounted ducted unit. This extremely powerful unit’s compact design allows it to be completely concealed – and it’s perfect for offices, restaurants, shops or even hotel ballrooms.
OSA
Outside air integration possible
Condensate pump as standard
Auto adjust External Static Pressure n A 0007 fter installation, it is possible the actual duct resistance is lower than expected at the time of designing. As a consequence, the air flow will be too high. n With 00070007 the automatic air flow adjustment function the unit can adapt its fan speed to a lower curve, so the air flow decreases. n The 00070007 air flow will always be within 10% of the rated air flow because of the amount of possible fan curves (more than 8 fan curves available per model). n A 0007 lternatively the installer can manually select a fan curve with the wired remote control.
Application n n n n n
H 0007 otels/Conference centers M 0007 ulti-family residences S0007 ingle family residences O 0007 ffices R 0007 etail
Airflow (cfm)
± 10%
Fan characteristic curve Actual duct resistance curve Duct resistance curve at the time of designing Rated airflow Airflow with out airflow automatic adjustment Actual airflow
Features and Benefits n N 0007 ew ducted indoor unit designed to unify the FXSQ and FXMQ range with the best features taken from both units n 00070007Available from 7.5 MBH to 48 MBH n 00070007Improved efficiency with our new DC fan motor n 0007Auto adjusting airflow at commissioning based on ESP n 00070007Medium ESP capabilities of up to 0.8” W.G. n 00070007Three user selected fan speeds available plus fan “Auto” logic n 00070007Low profile design – less that 12” high n 0007Built-in condensate pump
A B SO L U T E C O MF O RT
6
n Indoor 00070007 Air Quality options include filters (MERV 8 and 13) and UV Air Cleaner Module n 00070007Service access from below
DAIKIN AC
FXMQ_P Specifications FXMQ_P Specifications
0.6-Ton
0.75-Ton
1-Ton
1.5-Ton
2-Ton
2.5-Ton
3-Ton
4-Ton
Model Name FXMQ07PVJU FXMQ09PVJU FXMQ12PVJU FXMQ18PVJU FXMQ24PVJU FXMQ30PVJU FXMQ36PVJU FXMQ48PVJU Power Supply V/ph/Hz 208-230/1/60 Cooling Capacity Btu/h 7,500 9,500 12,000 18,000 24,000 30,000 36,000 48,000 Heating Capacity Btu/h 8,500 10,500 13,500 20,000 27,000 34,000 40,000 54,000 Refrigerant R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A Refrigerant Control Electronic Expansion Valve Airflow Rate HH/H/L cfm 317/264/229 317/264/229 335/282/246 635/582/529 688/618/565 882/794/706 1,130/953/812 1,377/1,165/988 Unit Weight lbs. 55 55 55 80 80 80 102 102 Unit Height in. 11 13/16 11 13/16 11 13/16 11 13/16 11 13/16 11 13/16 11 13/16 11 13/16 Unit Width in. 21 5/8 21 5/8 21 5/8 39 3/8 39 3/8 39 3/8 55 1/8 55 1/8 Unit Depth in. 27 9/16 27 9/16 27 9/16 27 9/16 27 9/16 27 9/16 27 9/16 27 9/16 Sound Pressure H/L dB(A) 33/29 33/29 34/29 41/37 42/38 43/39 43/39 44/40 External Static Pressure in. W.G. 0.40/0.12 0.40/0.12 0.40/0.12 0.80/0.20 0.80/0.20 0.80/0.20 0.80/0.20 0.80/0.20 (High/Low) Unit Condensate in. O.D. 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 Connection Condensate Pump Lift in. 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 Liquid in. 1/4 Flare 1/4 Flare 1/4 Flare 1/4 Flare 3/8 Flare 3/8 Flare 3/8 Flare 3/8 Flare Pipe Connections Gas in. 1/2 Flare 1/2 Flare 1/2 Flare 1/2 Flare 5/8 Flare 5/8 Flare 5/8 Flare 5/8 Flare External Finish Galvanized Steel Plate Fuse Protection Devices Fan Driver Overload Protector Recommended Fuse/ A 15 15 15 15 15 15 15 15 Breaker Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
Note: Specifications are subject to change without notice.
FXMQ_P Accessories Model Name FXMQ07PVJU FXMQ09PVJU FXMQ12PVJU FXMQ18PVJU Navigation Remote Controller BRC1E71 BRC1E71 BRC1E71 BRC1E71 Simplified Wired Remote Controller* BRC2A71 BRC2A71 BRC2A71 BRC2A71 Wireless Remote Controller BRC4C82 BRC4C82 BRC4C82 BRC4C82 Remote Sensor Kit KRCS01-4B KRCS01-4B KRCS01-4B KRCS01-4B Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA KRP1B71 KRP1B71 KRP1B71 KRP1B71
FXMQ24PVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-4B
FXMQ30PVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-4B
FXMQ36PVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-4B
FXMQ48PVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-4B
KRP1B71
KRP1B71
KRP1B71
KRP1B71
KRP4A71
KRP4A71
KRP4A71
KRP4A71
damper/fan)
Group Control Adaptor PCB (connects to external BMS)
KRP4A71
KRP4A71
KRP4A71
KRP4A71
* Optional face plates available to provide a more intuitive user interface and disable specific functions
FXMQ_P Installation Space Air Inlet
a
a
Ceiling (length: in.)
18” or more
Ceiling Floor Surface
A B SO L UT E C OM F O RT
Air Outlet
Floor Surface
a = 12” or more if one inspection hatch (17“ 3/4 x 17” 3/4) on the control box side and a space of 11“ 13/16 or more under the unit. a = 1” or more if an inspection hatch the size of the indoor unit plus an additional 12” or more on the control box side is installed.
INDOOR w w w. d a i k i n a c . c o m
7
Concealed Ceiling Unit (medium static) FXMQ_MVJU Concealed. Slim design. Strong. Comfortable. The new FXMQ_MVJU ducted fan coil unit is ideal for larger open space floor plans usually found in offices, retails, hotels or education facilities. It is a perfect addition to Daikin’s line up of ducted units that performs well across multiple spaces that can benefit from the same mode of operation, limiting equipment and installation cost.
OSA
Outside air integration possible
Features and Benefits n G 0007 reater design flexibility with a capacity range extended
to 96 MBH n I0007mproved ductwork and filtration flexibility with high CFM
and ESP capabilities of up to 1.1” W.G. n L0007 ow profile design of less than 19” high to reduce required
installation space n B 0007 uilt-in condensate float switch (condensate pump is
not included)
A B SO L U T E C O MF O RT
8
DAIKIN AC
Application n n n n n
H 0007 otel/Conference centers S0007 chools R 0007 etail/Shopping centers L0007 arge open plan offices C 0007 hurches
FXMQ_M Specifications FXMQ_M Specifications Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L External Static Pressure (Nominal/Maximum) Unit Condensate Connection Liquid Pipe Connections Gas External Finish
6-Ton V/ph/Hz Btu/h Btu/h
cfm lbs. in. in. in. dB(A) in. W.G.
0.38/0.95
in. O.D. in. in.
1 1 3/8 Flare 3/8 Flare 3/4 Flare 7/8 Flare Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15 15
Protection Devices Recommended Fuse/Breaker
A
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
8-Ton
FXMQ72MVJU FXMQ96MVJU 208-230/1/60 72,000 96,000 81,000 108,000 R-410A R-410A Electronic Expansion Valve 2,047 / 1,764 2,541 / 2,188 302 302 18 1/8 18 1/8 54 3/8 54 3/8 43 5/16 43 5/16 48/45 48/45 0.43/0.95
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
Note: Specifications are subject to change without notice.
FXMQ_M Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor Kit Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB (connects to external BMS)
FXMQ72MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXMQ96MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
KRP1B71
KRP1B71
KRP4A71
KRP4A71
High Efficiency Filter Kit (MERV 13) DACA-MQ96M-13-1K DACA-MQ96M-13-1K High Efficiency Filter Kit (MERV 8) DACA-MQ96M-8-1K DACA-MQ96M-8-1K * Optional face plates available to provide a more intuitive user interface and disable specific functions
FXMQ_M Installation Space
Air Inlet
a
a
Ceiling (length: in.)
18” or more
Ceiling Floor Surface
A B SO L UT E C OM F O RT
Air Outlet
Floor Surface
a = 12” or more if one inspection hatch (17“ 3/4 x 17” 3/4) on the control box side and a space of 11“ 13/16 or more under the unit. a = 1” or more if an inspection hatch the size of the indoor unit plus an additional 12” or more on the control box side is installed.
INDOOR w w w. d a i k i n a c . c o m
9
Slim Duct Built-In Concealed Ceiling Unit FXDQ_MVJU Concealed. Slim. Quiet. Comfortable The slim duct built-in concealed unit is available for use with the VRV systems to complement the existing concealed ceiling unit options (FXMQ). With its low profile and low sound level this unit can be installed into limited ceiling void, bulkhead or soffit space.
Condensate pump as standard
OSA
Outside air integration possible
Filter included
Application n n n n n
H 0007 otel rooms M 0007 ulti-family residences S0007 ingle family residences S0007 chool dormitories R 0007 etail
Features and Benefits n S0007 lim height, at only 7 7/8”, makes it suitable for most of the applications where attic / bulkhead space is limited n W 0007 ith a sound level as low as 29 dB(A) for the 7.5, 9 or 12 MBH indoor unit, these units are among the quietest on the market n F0007 actory set rear suction; bottom suction is possible to reverse n Washable filter included n C 0007 ondensate pump with vertical lift of up to 21 5/8” included as standard n B 0007 lends unobtrusively with any interior decor; only the suction and discharge grills are visible n M 0007 edium static pressure facilitates unit use with flexible ducts of varying length
A B SO L U T E C O MF O RT
10
DAIKIN AC
FXDQ Specifications FXDQ Specifications Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L External Static Pressure (High/Low) Unit Condensate Connection Condensate Pump Lift Liquid Pipe Connections Gas External Finish
0.6-Ton
0.75-Ton
FXDQ07MVJU
FXDQ09MVJU
7,500 8,500 R-410A
9,500 10,500 R-410A
cfm lbs. in. in. in. dB(A)
280/226 51 7 7/8 27 9/16 24 7/16 33/29
280/226 51 7 7/8 27 9/16 24 7/16 33/29
in. W.G.
0.12/0.04
0.12/0.04
in. O.D. in. in. in.
1 1/32 21 5/8 1/4 Flare 1/2 Flare
1 1/32 21 5/8 1/4 Flare 1/2 Flare
A
15
15
V/ph/Hz Btu/h Btu/h
Protection Devices Recommended Fuse/Breaker Standard Filter Type
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
1-Ton
1.5-Ton
2-Ton
FXDQ12MVJU FXDQ18MVJU 208-230/1/60 12,000 18,000 13,500 20,000 R-410A R-410A Electronic Expansion Valve 280/226 440/350 51 63 7 7/8 7 7/8 27 9/16 35 7/16 24 7/16 24 7/16 33/29 35/31 0.12/0.04
FXDQ24MVJU 24,000 27,000 R-410A 580/460 71 7 7/8 43 5/16 24 7/16 36/32
0.17/0.06
0.17/0.06
1 1/32 1 1/32 21 5/8 21 5/8 1/4 Flare 1/4 Flare 1/2 Flare 1/2 Flare Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15 15 Removable, Washable, Mildew Proof
1 1/32 21 5/8 3/8 Flare 5/8 Flare
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
15
Note: Specifications are subject to change without notice.
FXDQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor Kit Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB (connects to external BMS)
FXDQ07MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXDQ09MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXDQ12MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXDQ18MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXDQ24MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
KRP1B71-D
KRP1B71-D
KRP1B71-D
KRP1B71-D
KRP1B71-D
KRP4A74
KRP4A74
KRP4A74
KRP4A74
KRP4A74
APFXDQ18 APRFFXDQ18 APRFFXDQ18F
APFXDQ24 APRFFXDQ24 APRFFXDQ24F
APFXDQ070912 APFXDQ070912 APFXDQ070912 Access Panel (single door) APRFFXDQ070912 APRFFXDQ070912 APRFFXDQ070912 Access Panel with return air filter (single door) APRFFXDQ070912F APRFFXDQ070912F APRFFXDQ070912F Filter Media Replacement * Optional face plates available to provide a more intuitive user interface and disable specific functions
FXDQ Installation Space Choose an installation site that ensures both optimum air distribution and sufficient clearance for maintenance.
The return air inlet can be easily changed from rear to bottom using the same chamber lid.
Protection net Air inlet 12” or more
Control Box
Maintenance Space
Chamber lid
13/16” or more
Celing
H= 9-1/2”or more
7-7/8”
Chamber lid Air discharge
Floor surface (length : in.)
Protection net Air discharge
A B SO L UT E C OM F O RT
Maintenance Space
100”or more
12” or more
INDOOR Air inlet
w w w. d a i k i n a c . c o m
11
Round Flow Ceiling-Mounted Cassette FXFQ_PVJU
For use with:
Quiet. Elegant. Customizable. Low-maintenance. Comfortable. The Round Flow cassette is ideal for open plan applications such as classrooms and offices where variances in temperature and airflow can cause discomfort. With 23 configurable airflow distribution patterns, it can also be effective in smaller, more intricate spaces too. Condensate pump as standard
OSA
Outside air integration possible
Filter included
Features and Benefits n 360° airflow to reduce drafts and improve comfort n M 0007 odels range from 9 MBH to 48 MBH n I0007mproved flexibility with 23 different possible airflow patterns, ensuring ideal air distribution to maximize comfort and savings n Lower air velocities for better room airflow distribution n R 0007 educed unit weight and improved efficiency with a light weight fan n Stain resistant and easily cleanable decoration panel coating n Silver ion antibacterial drain pan treatment n 3 user selectable fan speeds (HH, H and L)
Airflow directions For air discharge in 2 or 3 directions, it is necessary to make field settings by remote controller and to close the air outlet(s). Refer to the section FIELD SETTING in the installation manual of the optional blocking pad kit.
A B SO L U T E C O MF O RT
Example of airflow patterns 12
DAIKIN AC
Application n n n n
R 0007 etail S0007 chools O 0007 ffices R 0007 estaurants
FXFQ Specifications FXFQ Specifications
0.75-Ton
1-Ton
1.5-Ton
Model Name Power Supply Rated Cooling Capacity Rated Heating Capacity Refrigerant Refrigerant Control Airflow Rate HH/H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure HH/H/L Unit Condensate Connection Condensate Pump Lift Gas Pipe Connections Liquid External Finish
FXFQ09PVJU
FXFQ12PVJU
FXFQ18PVJU
V/ph/Hz Btu/h Btu/h
9,500 10,500
12,000 13,500
cfm lbs. in. in. in. dB(A) in. O.D. in. in. in.
460/390/350 43 9 11/16 33 1/16 33 1/16 30/28/27 1 1/4 33 1/2 1/4 (Flare) 1/2 (Flare)
460/390/350 43 9 11/16 33 1/16 33 1/16 30/28/27 1 1/4 33 1/2 1/4 (Flare) 1/2 (Flare)
A
15
15
Protection Devices Recommended Fuse/Breaker Standard Filter Type
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
2-Ton
2.5-Ton
FXFQ24PVJU FXFQ30PVJU 208-230/1/60 18,000 24,000 30,000 20,000 27,000 34,000 R-410A Electronic Expansion Valve 560/470/390 780/620/470 830/670/530 43 48.5 48.5 9 11/16 9 11/16 9 11/16 33 1/16 33 1/16 33 1/16 33 1/16 33 1/16 33 1/16 32/30/27 36/32/28 38/35/31 1 1/4 1 1/4 1 1/4 33 1/2 33 1/2 33 1/2 1/4 (Flare) 3/8 (Flare) 3/8 (Flare) 1/2 (Flare) 5/8(Flare) 5/8(Flare) Galvanized Steel Plate Fuse/Breaker Fan Motor Thermal Protector 15 15 15 Mold Resistant Resin Net
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
3-Ton
4-Ton
FXFQ36PVJU
FXFQ48PVJU
36,000 40,000
48,000 54,000
1,180/910/700 1,220/970/790 55 55 11 5/16 11 5/16 33 1/16 33 1/16 33 1/16 33 1/16 44/38/32 45/40/34 1 1/4 1 1/4 33 1/2 33 1/2 3/8 (Flare) 3/8 (Flare) 5/8(Flare) 5/8(Flare)
15
15
Note: Specifications are subject to change without notice.
FXFQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor Kit Decoration Panel Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB (connects to external BMS)
FXFQ09PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
FXFQ12PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
FXFQ18PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
FXFQ24PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
FXFQ30PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
FXFQ36PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
FXFQ48PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
KRP1C75
KRP1C75
KRP1C75
KRP1C75
KRP1C75
KRP1C75
KRP1C75
KRP4A74
KRP4A74
KRP4A74
KRP4A74
Long-Life Replacement Filter KAFP551K160 KAFP551K160 KAFP551K160 KAFP551K160 Panel Spacer KDBP55H160FA KDBP55H160FA KDBP55H160FA KDBP55H160FA Fresh Air Intake Kit with T pipe KDDP55B160K KDDP55B160K KDDP55B160K KDDP55B160K Fresh Air Intake Kit without T pipe KDDP55B160 KDDP55B160 KDDP55B160 KDDP55B160 * Optional face plates available to provide a more intuitive user interface and disable specific functions
KRP4A74
KRP4A74
KRP4A74
KAFP551K160 KDBP55H160FA KDDP55B160K KDDP55B160
KAFP551K160 KDBP55H160FA KDDP55B160K KDDP55B160
KAFP551K160 KDBP55H160FA KDDP55B160K KDDP55B160
FXFQ Installation Space
*60” or more
Air discharge
Air inlet
Air discharge *60” or more
H
Air inlet *60” or more Air discharge Air discharge *60” or more
Floor Surface (NOTE) Leave 7 7/8” or more space where marked with the *, on sides where the air outlet is closed.
At least 70” from the floor
H 10” 11 3/4” or more
A B SO L UT E C OM F O RT
H
Model FXFQ09 • 12 • 18 • 24 • 30PVJU FXFQ36 • 48PVJU
INDOOR w w w. d a i k i n a c . c o m
13
2’ x 2’ 4-way Ceiling-mounted cassette FXZQ_M7VJU Soft. Elegant. Customizable. Low-maintenance. Comfortable. From corner stores to offices and classrooms, our elegant ceilingmounted cassette units provide low-noise, customizable comfort. Airflow can be sent in any of four directions, and the ability to shut down one or two sides allows for easy corner installation. For easier installation, units fit in a standard 2’ x 2’ ceiling grid.
Condensate pump as standard
OSA
Outside air integration possible
Filter included
Features and Benefits Application n R 0007 etail n S 0007 chools n O 0007 ffices
n Sound pressure levels are as low as 29 dB(A) n 0007Space-saving depth of units requires only 11.6” of ceiling space n T0007 hree auto-swing positions to choose from – standard, draft prevention and ceiling stain prevention n S0007 imple installation with an easy-to-fit decoration panel, easy height adjustment and a suction grille that can rotate up to 90° n E0007 asy-to-clean grille, washable long-life filter and optional high efficiency filters n Trouble-free condensate pump inside the unit n 0007Models range from 7.5 MBH to 18 MBH
Airflow directions For air discharge in 2 or 3 directions, it is necessary to make field settings by remote controller and to close the air outlet(s). Refer to the section FIELD SETTING in the installation manual of the optional blocking pad kit.
A B SO L U T E C O MF O RT
Example of airflow patterns 14
DAIKIN AC
FXZQ Specifications FXZQ Specifications
0.6-Ton
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Condensate Pump Lift Liquid Pipe Connections Gas External Finish
FXZQ07M7VJU V/ph/Hz Btu/h Btu/h
7,500 8,700 R-410A
cfm lbs. in. in. in. dB(A) in. O.D. in. in. in.
320/247 42 11 1/4 22 5/8 22 5/8 31/29 1 1/32 21 1/2 1/4 Flare 1/2 Flare
A
15
Protection Devices Recommended Fuse/Breaker Standard Filter Type
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
0.75-Ton
1-Ton
FXZQ09M7VJU FXZQ12M7VJU 208-230/1/60 9,500 12,000 11,100 14,000 R-410A R-410A Electronic Expansion Valve 335/265 495/353 42 42 11 1/4 11 1/4 22 5/8 22 5/8 22 5/8 22 5/8 33/29 41/34 1 1/32 1 1/32 21 1/2 21 1/2 1/4 Flare 1/4 Flare 1/2 Flare 1/2 Flare Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15 15 Resin Net (with Mold Resistant)
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
1.5-Ton FXZQ18M7VJU 18,000 21,000 R-410A 495/353 42 11 1/4 22 5/8 22 5/8 41/34 1 1/32 21 1/2 1/4 Flare 1/2 Flare
15
Note: Specifications are subject to change without notice.
FXZQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Remote Sensor Kit Decoration Panel Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
FXZQ07M7VJU BRC1E71 BRC2A71 KRCS01-1B BYFQ60BU
FXZQ09M7VJU BRC1E71 BRC2A71 KRCS01-1B BYFQ60BU
FXZQ12M7VJU BRC1E71 BRC2A71 KRCS01-1B BYFQ60BU
FXZQ18M7VJU BRC1E71 BRC2A71 KRCS01-1B BYFQ60BU
KRP1B72
KRP1B72
KRP1B72
KRP1B72
KAFQ441B60 KDBHQ44B60 KDBQ44B60 KDDQ44XA60
KAFQ441B60 KDBHQ44B60 KDBQ44B60 KDDQ44XA60
Long-Life Replacement Filter KAFQ441B60 KAFQ441B60 Sealing Member of Air Discharge Outlet KDBHQ44B60 KDBHQ44B60 Panel Spacer KDBQ44B60 KDBQ44B60 Fresh Air Intake Kit KDDQ44XA60 KDDQ44XA60 * Optional face plates available to provide a more intuitive user interface and disable specific functions
FXZQ Installation Space
H
Air discharge
Air inlet
Air discharge *59 or more
H 11.6 or more (length: in.)
Air inlet *59 or more Air discharge Air discharge *59 or more A B SO L UT E C OM F O RT
*59 or more
H
Model FXZQ07-18M7VJU
(NOTE) Leave 7 7/8 or more space where marked with the *, on sides where the air outlet is closed.
INDOOR w w w. d a i k i n a c . c o m
15
Wall-mounted Unit FXAQ_MVJU
Stylish. Compact. Convenient. Comfortable. Our wall-mounted units are ideal for cooling or heating smaller zones such as hotel rooms, stores, small offices and restaurants. The compact, stylish design lets the unit blend discreetly into any interior design, and airflow can be sent in any of five different directions and programmed via remote control.
Filter included
Features and Benefits n A 0007 uto-swing mechanism ensures efficient air distribution via louvers that automatically close when the unit is turned off n Wide 00070007 air discharge outlet distributes a comfortable airflow throughout the entire space n Horizontal 00070007 louvers and front panel can be easily removed for cleaning n 0007Drain pipe can be easily hidden from sight n 0007Models range from 7.5 MBH to 24 MBH
A B SO L U T E C O MF O RT
16
DAIKIN AC
Application n n n n n
R 0007 etail R 0007 estaurants O 0007 ffices H 0007 otels M 0007 ulti-family residences
FXAQ Specifications FXAQ Specifications Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Liquid Pipe Connections Gas External Finish
0.6-Ton
0.75-Ton
FXAQ07MVJU
FXAQ09MVJU
7,500 8,500 R-410A
9,500 10,500 R-410A
cfm lbs. in. in. in. dB(A) in. O.D. in. in.
260/160 25 11 3/8 31 1/4 9 36/31 11/16 1/4 1/2
280/175 25 11 3/8 31 1/4 9 37/31 11/16 1/4 1/2
A
15
15
V/ph/Hz Btu/h Btu/h
Protection Devices Recommended Fuse/Breaker Standard Filter Type
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
1-Ton
1.5-Ton
2-Ton
FXAQ12MVJU FXAQ18MVJU 208-230/1/60 12,000 18,000 13,500 20,000 R-410A R-410A Electronic Expansion Valve 300/180 500/400 25 31 11 3/8 11 3/8 31 1/4 41 3/8 9 9 38/31 43/37 11/16 11/16 1/4 1/4 1/2 1/2 White Casing Fuse Fan Motor Thermal Protector 15 15 Resin Net (washable)
FXAQ24MVJU 24,000 27,000 R-410A 635/470 31 11 3/8 41 3/8 9 47/40 11/16 3/8 5/8
15
Note: Specifications are subject to change without notice.
FXAQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor Kit Group Control Adaptor PCB (connects to external BMS)
FXAQ07MVJU BRC1E71 BRC2A71 BRC7E818 KRCS01-1B
FXAQ09MVJU BRC1E71 BRC2A71 BRC7E818 KRCS01-1B
FXAQ12MVJU BRC1E71 BRC2A71 BRC7E818 KRCS01-1B
FXAQ18MVJU BRC1E71 BRC2A71 BRC7E818 KRCS01-1B
FXAQ24MVJU BRC1E71 BRC2A71 BRC7E818 KRCS01-1B
KRP4A71
KRP4A71
KRP4A71
KRP4A71
KRP4A71
DACA-CP1-1
DACA-CP1-1
Condensate Pump DACA-CP1-1 DACA-CP1-1 DACA-CP1-1 * Optional face plates available to provide a more intuitive user interface and disable specific functions
FXAQ Installation Space [ Space required for installaion (in.) ] ≥2
≥2
≥ 3 1/2
Installation panel (1)
Fig.1
Left pipe
Obstruction ≤ 4 3/4
≥ 100 (from floor) For installation in high places.
Back-left pipe Bottom-left pipe Back-right pipe
Floor Fig. 2
Fig.3
Bottom-right pipe
A B SO L UT E C OM F O RT
≥ 1 1/4
Temporary screw (In case of 12 type)
INDOOR w w w. d a i k i n a c . c o m
17
Ceiling Suspended Unit FXHQ_MVJU Slim. Efficient. Quiet. Easy to Maintain. With its slim, elegant design, the FXHQ ceiling-suspended unit is a great fit for any light commercial space. Wide air openings provide a comfortable airflow and an innovative stream fan ensures quiet operation, making it ideal for retail stores, restaurants, classrooms and conference rooms.
Filter included
Application n R 0007 etail/Shops n O 0007 ffices n R 0007 estaurants
Features and Benefits n O 0007 ne of our slimmest indoor units (less than 8”) fits within any interior design n W 0007 ide air discharge outlet distributes a comfortable airflow throughout the entire space n 00070007Innovative stream fan technology keeps sound pressure levels low n 00070007Installation is fast and optional drain-up kit can be added easily n 0007Bristle-free, non-dew flap and flat design make cleaning simple n 0007Long-life filter (maintenance-free for up to one year) is standard n 0007Models range from 12 MBH to 36 MBH
A B SO L U T E C O MF O RT
18
DAIKIN AC
FXHQ Specifications FXHQ Specifications
1-Ton
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Liquid Pipe Connections Gas External Finish
V/ph/Hz Btu/h Btu/h
cfm lbs. in. in. in. dB(A) in. O.D. in. in.
Protection Devices Recommended Fuse/Breaker Standard Filter Type Nominal Conditions:
2-Ton
3-Ton
FXHQ12MVJU
A
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
FXHQ24MVJU FXHQ36MVJU 208-230/1/60 12,000 24,000 36,000 13,500 27,000 40,000 R-410A R-410A R-410A Electronic Expansion Valve 410/340 710/600 830/670 55 80 90 7 11/16 7 11/16 7 11/16 37 13/16 55 1/8 62 5/8 26 3/4 26 3/4 26 3/4 42/33 44/36 46/41 1 1 1 1/4 3/8 3/8 1/2 5/8 5/8 White Casing Fuse Fan Motor Thermal Protector 15 15 15 Resin Net (with Mold Resistant)
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
Note: Specifications are subject to change without notice.
FXHQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor Kit Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB (connects to external BMS)
FXHQ12MVJU BRC1E71 BRC2A71 BRC7E83 KRCS01-1B
FXHQ24MVJU BRC1E71 BRC2A71 BRC7E83 KRCS01-1B
FXHQ36MVJU BRC1E71 BRC2A71 BRC7E83 KRCS01-1B
KRP1B71
KRP1B71
KRP1B71
KRP4A72
KRP4A72
KRP4A72
Replacement long-life filter KAFJ501D56 KAFJ501D112 KAFJ501D160 L-type piping kit KHFP5M35 KHFP5M63 KHFP5M160 * Optional face plates available to provide a more intuitive user interface and disable specific functions
FXHQ Installation Space
1 3/16 or more
Air outlet Required service space
Air inlet
1 3/16 or more
12 or more
A B SO L UT E C OM F O RT
Obstruction Floor
INDOOR w w w. d a i k i n a c . c o m
19
Floor-Standing Units FXLQ_MVJU/FXNQ_MVJU
Versatile. Logical. Durable. Quiet. The ideal way to save space, our floor-standing units can easily be installed along a perimeter wall – or concealed. The air distribution from these models will allow you to find the right balance for classrooms, hospital rooms, office hallways or similar spaces.
OSA
Outside air integration possible (FXNQ) Filter included
FXLQ FXNQ
Features and Benefits n 00070007Ideal for installation beneath a window n 0007Unit requires minimal installation space n 00070007Fitted with a washable long-life filter n 0007Remote-control options available n S0007 pace-saving unit can be freestanding or wall-mounted, concealed or exposed n 0007Models range from 12 MBH to 24 MBH
A B SO L U T E C O MF O RT
20
DAIKIN AC
Application n n n n n n
M 0007 ulti-family residences S0007 ingle family residences C 0007 hurches H 0007 istoric buildings S0007 chools O 0007 ffices
FXLQ/FXNQ Specifications FXLQ/FXNQ Specifications Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Liquid Pipe Connections Gas External Finish
2-Ton
FXLQ18MVJU FXLQ24MVJU 208-230/1/60 12,000 18,000 24,000 13,500 20,000 27,000 R-410A R-410A R-410A Electronic Expansion Valve 280/210 490/380 560/420 66 80 80 23 5/8 23 5/8 23 5/8 44 7/8 55 7/8 55 7/8 8 3/4 8 3/4 8 3/4 36/33 40/35 41/36 27/32 27/32 27/32 1/4 1/4 3/8 1/2 1/2 5/8 Ivory White Casing Fuse Fan Motor Thermal Protector 15 15 15 Resin Net (with Mold Resistant)
V/ph/Hz Btu/h Btu/h
cfm lbs. in. in. in. dB(A) in. O.D. in. in.
Recommended Fuse/Breaker Standard Filter Type
A
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Concealed 1.5-Ton
1-Ton
FXLQ12MVJU
Protection Devices
Nominal Conditions:
Exposed 1.5-Ton
1-Ton
2-Ton
FXNQ12MVJU
FXNQ18MVJU FXNQ24MVJU 208-230/1/60 12,000 18,000 24,000 13,500 20,000 27,000 R-410A R-410A R-410A Electronic Expansion Valve 280/210 490/380 560/420 51 60 60 24 24 24 42 1/8 53 1/8 53 1/8 8 5/8 8 5/8 8 5/8 36/33 40/35 41/36 27/32 27/32 27/32 1/4 1/4 3/8 1/2 1/2 5/8 Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15 15 15 Resin Net (with Mold Resistant)
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
Note: Specifications are subject to change without notice.
FXLQ/FXNQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor Kit Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB (connects to external BMS)
FXLQ12MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXLQ18MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXLQ24MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXNQ12MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXNQ18MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXNQ24MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
KRP1B71
KRP1B71
KRP1B71
KRP1B71
KRP1B71
KRP1B71
KRP4A71
KRP4A71
KRP4A71
KRP4A71
KRP4A71
KRP4A71
* Optional face plates available to provide a more intuitive user interface and disable specific functions
FXLQ/FXNQ Installation Space FXNQ
FXLQ
24 5/8 3 1/8 or more
Window
Maintenance area
A
or
Front side 4 or more (FXLQ) 40 or more
6 or more (FXNQ)
(IMPORTANT) Leave sufficient clearance for air inlet and maintenance. Model
Air inlet direction Base (length: in.)
A (in.)
B (in.)
FXNQ12MVJU
28
46
FXNQ18 · 24MVJU
39
57
A B SO L UT E C OM F O RT
3/4 or more
(length: in.) Air flow direction 70 or more
4 or more (FXLQ)
m
o r m re or e
Bo
INDOOR w w w. d a i k i n a c . c o m
21
100% Outside Air Processing Unit FXMQ_MFVJU Concealed. Powerful. Compact. Quiet. Fresh Air Quality. Both fresh air treatment and heating and cooling can be achieved successfully in a single system via heat pump technology without the usual design problems associated with balancing air supply and discharge. Fan coil units and outdoor air processing unit can be connected to the same refrigerant line, resulting in enhanced design flexibility and a significant reduction in total system costs.
Operational Characteristics
Features and Benefits
When the suction air temperature is between 66°F and 109°F the Outside Air Processing Unit operates in cooling, and when between 23°F and 59°F, it operates in heating. The OA processing unit will work in energy saving fan only between 59°F and 66°F; this is not configurable.
n C 0007 an be connected to all North American Daikin VRV systems
66°F
23°F
n A 0007 vailable in three capacities, nominal 48, 72 and 96 MBH n T0007 he nominal airflow are 635, 988, and 1,236 CFM respectively
109°F
n I0007ndoor Air Quality options include MERV 8 and 13 filters and filter boxes
Heating A B SO L U T E C O MF O RT
22
n C 0007 onnects directly and seamlessly into the Daikin local and centralized control suite
Fan only operation
Operation limit (heating)
23
32
DAIKIN AC
43
Cooling 59
n T0007 he indoor unit is controlled to a set cooling and heating discharge air temperature allowing the flexibility to integrate with a standard Daikin indoor unit or duct directly to the space n A 0007 low profile design of only 18.5” high reduces the required installation space and can eliminate mechanical rooms or additional structural supports associated with traditional OA systems
Operation limit (cooling)
59°F
n E0007 xternal static pressure capabilities of up to 1.03” W.G. allows for flexibility with duct work and filtration choices
66
64
92
107 109
FXMQ_MFVJU Specifications FXMQ_MFVJU Specifications V/ph/Hz Btu/h Btu/h cfm lbs. in. in. in. dB(A) in. W.G. in. in.
Liquid Gas
Pipe Connections
4-Ton FXMQ48MFVJU
Model Name Power Supply Cooling Capacity Heating Capacity Airflow Rate Unit Weight Unit Height Unit Width Unit Depth Sound Pressure External Static Pressure
48,000 30,000 635 190 18 1/2 29 1/4 43 5/16 42 0.88 3/8 5/8
External Finish Protection Devices Operating Range - Cooling Operating Range - Heating Discharge Air Temp. - Cooling Discharge Air Temp. - Heating
°F °F °F °F
Cooling Mode Discharge Set Temperature: 64 °F DB Outdoor: 91 °F DB, 82 °F WB (68% RH) Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
6-Ton
8-Ton
FXMQ72MFVJU FXMQ96MFVJU 208-230/1/60 72,000 96,000 47,000 59,000 988 1,236 271 271 18 1/2 18 1/2 54 3/8 54 3/8 43 5/16 43 5/16 47 47 0.96 1.03 3/8 3/8 3/4 7/8 Galvanized Steel Plate Fuse Fan Motor Thermal Protector 66 DB/59 WB - 95 DB/90 WB 23 DB to 68 DB 55 - 77 64 - 86
Heating Mode Discharge Set Temperature: 77 °F DB Outdoor: 32 °F DB, 27 °F WB (50% RH) Pipe Length: 25 ft. Level Difference: 0 ft.
Connection Rules n W 0007 hen the Outside Air Processing Unit (OA processing unit) is used in conjunction with standard indoor unit(s) on a single piping network, the total combined connected capacity ratio of standard indoor unit(s) and OA processing unit must be equal or within 50% and 100% of the capacity of the condensing unit. In addition, the connected capacity of the OA processing unit must be equal or less than 30% of the capacity of the condensing unit. n W 0007 hen the condensing unit is dedicated to the OA processing unit, the connected capacity of the OA processing unit must be equal or within 50% to 100% of the capacity of the condensing unit.
Note: Specifications are subject to change without notice.
FXMQ_MFVJU Accessories Model Name Navigation Remote Controller Wireless Remote Controller Remote Sensor Kit Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB (connects to external BMS)
High Efficiency Filter Kit (MERV 13) High Efficiency Filter Kit (MERV 8)
FXMQ48MFVJU BRC1E71 BRC4C82 KRCS01-1B
FXMQ72MFVJU BRC1E71 BRC4C82 KRCS01-1B
FXMQ96MFVJU BRC1E71 BRC4C82 KRCS01-1B
KRP1B71
KRP1B71
KRP1B71
KRP4A71
KRP4A71
KRP4A71
DACA-MQ48F-13-1K DACA-MQ96F-13-1K DACA-MQ96F-13-1K DACA-MQ48F-8-1K DACA-MQ96F-8-1K DACA-MQ96F-8-1K
FXMQ_MFVJU Layout Example VRVIII Series Outdoor Units
Indoor Unit
Indoor Unit
Outdoor Air processing unit
Outside air supply
Air-conditioning
Discharge Side
Suction Side
2.5” or more
(length: in.)
A B SO L UT E C OM F O RT
FXMQ_MFVJU Installation Space
Ceiling
2.5” or more
25 9/16” or more Ceiling
INDOOR w w w. d a i k i n a c . c o m
23
WARNINGS: • 0007Always use a licensed installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. • 0007Use only those parts and accessories supplied or specified by Daikin. Ask a licensed contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. • 0007Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. For any inquiries, contact your local Daikin sales office.
© 2011 Daikin Industries, Limited. Daikin , Daikin AC Absolute Comfort, and its design, VRV and REFNET ™ are trademarks pending or registered trademarks of Daikin Industries, Limited. All rights reserved. LonWorks and LON are registered trademarks of Echelon Corporation. BACnet is a Data Communication Protocol for Building Automation and Control Networks, developed under the auspices of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). ®
®
®
®
®
®
Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION
JMI-0107
Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, COMMERCIAL HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, MARINE TYPE CONTAINER REFRIGERATION UNITS, COMPRESSORS AND VALVES.
Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM.
All of the Daikin Group's business facilities and subsidiaries in Japan are certified under the ISO 14001 International standard for environmental management.
JQA-1452
Daikin AC (Americas), Inc.
Dealer Information
PCVINDUSE11-02C
Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations. w w w. d a i k i n a c . c o m
A B SO L UT E C OM F O RT
1645 Wallace Drive, Suite 110 Carrollton, TX 75006 USA www.daikinac.com [email protected] 866-4DAIKIN 972-245-1510
24
AIR COOLED
n
WATER COOLED
n
RESIDENTIAL
n
COMMERCIAL
n
RENOVATION
n
NEW CONSTRUCTION
VRV: The Components Condensing units
Air-Cooled Condensers
Water-Cooled Condenser
Heat Pump
Heat Pump or Heat Recovery
Heat Pump or Heat Recovery
3 and 4-Ton 208-230V/60Hz/1ph
6 to 16-Ton 208-230V60Hz/3ph or 460V/60Hz/3ph
6 to 21-Ton 208-230V/60Hz/3ph
REFNET® REFNET joints distribute an equal flow of refrigerant in every branch of the piping network.
A BSVQ changeover box is necessary for heat recovery applications.
Controls Individual Zone Controllers Navigation Wired R/C BRC1E71
Simplified Wired R/C BRC2A71
Wireless R/C BRC7C812 BRC7E83 BRC4C82 BRC7E818
®
LonWorks Networks Compatible Interface n Interface for LonWorks
A B SO L U T E C O MF O RT
2
networks n 0007Communication via LON protocol (twisted pair wire) n 64 units connectable per interface n Unlimited site size n Quick, easy installation
DAIKIN AC
Multi-Zone Controllers
Time Clock Controllers
Unified On/Off R/C DCS301C71
Schedule Timer DST301BA61
Centralized R/C DCS302C71
Integrated control system connecting VRV system with Building Management system n Interface for BMS system n Communication via BACnet®
protocol (BACnet/IP) n 256 units connectable per BACnet gateway (with DAM411B51) n Unlimited site size n Quick, easy installation ®
IMP-128/256/512/768/1,024
DCS601C71
n 1,024 indoor units (organized in
n 64 groups (128 indoor
n
n
n
n
up to 200 control groups) Management of AC units and ancillary equipment Operation on one master PC and one sub PC (sub PC option) Remote monitoring via the Web Alarm e-mail function
units) connectable
n Management of AC
units and ancillary equipment n Touch screen display n Built-in Ethernet port, Web enabled (optional) n Alarm e-mail function
VRV Indoor Units Capacity Range
Indoor Type
Page
MBH
7.5
09
12
18
24
30
36
42
48
54
72
96
Tons
0.6
0.75
1
1.5
2
2.5
3
3.5
4
4.5
6
8
OSA
OSA
OSA
OSA
OSA
OSA
OSA
OSA
FXTQ_PAVJU Vertical air handling unit (horizontal RHS is possible)
4
FXMQ_PVJU
Ducted
DC ducted concealed ceiling (medium static)
6 OSA
OSA
OSA
OSA
OSA
OSA
OSA
OSA
FXMQ_MVJU Concealed ceiling unit (medium static)
8 OSA
OSA
FXDQ_MVJU Slim duct built-in concealed ceiling unit
10 OSA
OSA
OSA
OSA
OSA
FXFQ_PVJU Round flow ceiling mounted cassette
12 OSA
OSA
OSA
OSA
OSA
OSA
OSA
FXZQ_M7VJU 2’ x 2’ 4-way ceiling mounted cassette
14 OSA
OSA
OSA
OSA
FXAQ_MVJU
Duct-free
Wall mounted unit
16
FXHQ_MVJU Ceiling suspended unit
18
FXLQ_MVJU Floor standing unit
20
FXNQ_MVJU Concealed floor standing unit
20 OSA
FXMQ_MFVJU 100% Outside Air Processing Unit
22 OSA
Available (11 types, 51 models) Condensate pump standard on model OSA
OSA
Outside air connection possible on model
OSA
OSA
A B SO L UT E C OM F O RT
Ventilation
OSA
INDOOR w w w. d a i k i n a c . c o m
3
Vertical Air Handling Unit FXTQ_PAVJU Concealed. Powerful. Compact. Comfortable. The upflow or horizontal (RHS) air handling unit is designed for use with all Daikin VRV® systems allowing more flexibility and combination possibilities. Ranging from 1 to 4 1/2 tons, the vertical air handling* unit by Daikin will take your next installation above and beyond your expectations. *Horizontal right configuration is possible
OSA
Outside air integration possible
Electric heater options Model Name FXTQ12PAVJU FXTQ18PAVJU FXTQ24PAVJU FXTQ30PAVJU FXTQ36PAVJU FXTQ42PAVJU FXTQ48PAVJU FXTQ54PAVJU
5kW
15kW
20kW
n
n
X
X
l
n
n
X
X
X
X
X
X
l
n
n
X
n
n
X
X
l
l
l
l
n
n
n
X
X
n
n
n
X
l
X
l
l
l
n
nu
X
l
l
l
l
n
nu
nu
l
l
l
l
n
nu
nu
l Electric heater operation with heat pump is allowed
X Not allowed
n Only electric heater operation is allowed
u Acceptable 2 step heating operation
The FXTQ_PAVJU represents an improvement in Electric Heater options and control logic versus previous units: n W 0007 ide line up of electric heat (field installed) options from 3kW to 20kW n 0007Integrated KRP1 function to minimize cost n 0007Electric heater operation in combination with heat pump operation (boost) is now possible n Reduced operational deadband A field supplied and installed Ground Fault Circuit Interrupter is required when utilizing the electric heat option
Features and Benefits
Application
n R 0007 educed installation time with integrated Electronic Expansion Valve and Printed Circuit Boards n 0007Improved application flexibility with the ability to mix and match with other Daikin indoor units on the same system n 0007Wider application range with dual voltage 208-230V/1ph/60Hz power supply n 0007Reduced piping cost with smaller piping diameters n 0007Only up flow and horizontal right installation is permitted n 0007Improved user comfort with 2 selectable fan speeds (H and L) n 0007New fan “Auto” logic allowing the unit to be commissioned where the fan operation will cycle on and off with the load n 0007The ECM fan motor as standard contributes to the increase in energy efficiency, reduction in sound and increased ESP (up to 0.5” W.G.) n 0007Ideal replacement for fan coils, vertical stacks or PTACs n 0007Replacement for geothermal heat pump and traditional split systems n 0007New construction or replacement
n n n n
A B SO L U T E C O MF O RT
4
Electrical heater capacity 6kW 8kW 10kW
3kW
DAIKIN AC
O 0007 ffices H 0007 otels M 0007 ulti-family residences S0007 ingle family residences
FXTQ Specifications FXTQ Specifications
1-Ton
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L External Static Pressure Range Unit Condensate Connection Gas Pipe Connections Liquid External Finish
V/ph/Hz Btu/h Btu/h
cfm lbs. in. in. in. dB(A) in. W.G. in. O.D. in. in.
Protection Devices Recommended Fuse/Breaker
A
1.5-Ton
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
2-Ton
2.5-Ton
3-Ton
3.5-Ton
4-Ton
4.5-Ton
FXTQ12PAVJU FXTQ18PAVJU FXTQ24PAVJU FXTQ30PAVJU FXTQ36PAVJU FXTQ42PAVJU FXTQ48PAVJU FXTQ54PAVJU 208-230/1/60 12,000 18,000 24,000 30,000 36,000 42,000 48,000 54,000 13,500 20,000 27,000 34,000 40,000 47,000 54,000 60,000 R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A Electronic Expansion Valve 400/280 600/420 800/560 1,000/700 1,200/840 1,400/980 1,600/1,120 1,800/1,260 119 119 145 145 145 167 167 167 46 3/4 46 3/4 53 1/4 53 1/4 53 1/4 53 1/4 53 1/4 53 1/4 19 1/2 19 1/2 22 22 22 22 22 22 22 22 24 24 24 24 24 24 n/a n/a n/a n/a n/a n/a n/a n/a up to 0.5 up to 0.5 up to 0.5 up to 0.5 up to 0.5 up to 0.5 up to 0.5 up to 0.5 3/4 (fpt) 3/4 (fpt) 3/4 (fpt) 3/4 (fpt) 3/4 (fpt) 3/4 (fpt) 3/4 (fpt) 3/4 (fpt) 1/2 (Braze) 1/2 (Braze) 5/8 (Braze) 5/8 (Braze) 5/8 (Braze) 5/8 (Braze) 5/8 (Braze) 5/8 (Braze) 1/4 (Braze) 1/4 (Braze) 3/8 (Braze) 3/8 (Braze) 3/8 (Braze) 3/8 (Braze) 3/8 (Braze) 3/8 (Braze) Fully insulated, painted steel cabinet with gray finish Fuse Fan Motor Thermal Protector 15 15 15 15 15 15 15 15 Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
Note: Specifications are subject to change without notice.
FXTQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor kit Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB
FXTQ12PAVJU FXTQ18PAVJU FXTQ24PAVJU FXTQ30PAVJU FXTQ36PAVJU FXTQ42PAVJU FXTQ48PAVJU FXTQ54PAVJU BRC1E71 BRC1E71 BRC1E71 BRC1E71 BRC1E71 BRC1E71 BRC1E71 BRC1E71 BRC2A71 BRC2A71 BRC2A71 BRC2A71 BRC2A71 BRC2A71 BRC2A71 BRC2A71 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 BRC4C82 KRCS01-4B KRCS01-4B KRCS01-4B KRCS01-4B KRCS01-4B KRCS01-4B KRCS01-4B KRCS01-4B KRP1C75 1
KRP1C75 1
KRP4A74 2
(connects to external BMS)
KRP1C75 1
KRP4A74 2
KRP1C75 1
KRP4A74 2
KRP1C75 1
KRP4A74 2
KRP1C75 1
KRP4A74 2
KRP1C75 1
KRP4A74 2
KRP1C75 1
KRP4A74 2
KRP4A74 2
External Control Adapter for Outdoor Unit DTA104A53 DTA104A53 DTA104A53 DTA104A53 DTA104A53 DTA104A53 DTA104A53 DTA104A53 2 Fixing Box KRP1B101 3 KRP1B101 3 KRP1B101 3 KRP1B101 3 KRP1B101 3 KRP1B101 3 KRP1B101 3 KRP1B101 3 Air Filter FIL 36-42 FIL 36-42 FIL 48-61 FIL 48-61 FIL 48-61 FIL 48-61 FIL 48-61 FIL 48-61 Insulation Kit (vertical) DPI 36-42/20 DPI 36-42/20 DPI 48-61/-20 DPI 48-61/-20 DPI 48-61/-20 DPI 48-61/-20 DPI 48-61/-20 DPI 48-61/-20 Insulation Kit (horizontal) DPIH 36-42 DPIH 36-42 DPIH48-61 DPIH48-61 DPIH48-61 DPIH48-61 DPIH48-61 DPIH48-61 1 Need 24VAC power supply 2 Need 16VDC power supply 3 Fixing box installed beside the unit * Optional face plates available to provide a more intuitive user interface and disable specific functions 2
2
2
2
2
2
2
FXTQ Installation Space
12” or more
12” or more
24” or more Ceiling
(length: in.)
Ensure there is sufficient space under the unit (see H dimension) so that return-air ductwork can be installed and a downward slope of 1/100 can be maintained for drain piping.
H
A B SO L UT E C OM F O RT
12” or more
INDOOR w w w. d a i k i n a c . c o m
5
DC Ducted Concealed Ceiling Unit (medium static) FXMQ_PVJU Concealed. Quiet. Compact. Comfortable. For small to large well-populated spaces in need of a concealed air-conditioning system, you can count on our ceiling mounted ducted unit. This extremely powerful unit’s compact design allows it to be completely concealed – and it’s perfect for offices, restaurants, shops or even hotel ballrooms.
OSA
Outside air integration possible
Condensate pump as standard
Auto adjust External Static Pressure n A 0007 fter installation, it is possible the actual duct resistance is lower than expected at the time of designing. As a consequence, the air flow will be too high. n With 00070007 the automatic air flow adjustment function the unit can adapt its fan speed to a lower curve, so the air flow decreases. n The 00070007 air flow will always be within 10% of the rated air flow because of the amount of possible fan curves (more than 8 fan curves available per model). n A 0007 lternatively the installer can manually select a fan curve with the wired remote control.
Application n n n n n
H 0007 otels/Conference centers M 0007 ulti-family residences S0007 ingle family residences O 0007 ffices R 0007 etail
Airflow (cfm)
± 10%
Fan characteristic curve Actual duct resistance curve Duct resistance curve at the time of designing Rated airflow Airflow with out airflow automatic adjustment Actual airflow
Features and Benefits n N 0007 ew ducted indoor unit designed to unify the FXSQ and FXMQ range with the best features taken from both units n 00070007Available from 7.5 MBH to 48 MBH n 00070007Improved efficiency with our new DC fan motor n 0007Auto adjusting airflow at commissioning based on ESP n 00070007Medium ESP capabilities of up to 0.8” W.G. n 00070007Three user selected fan speeds available plus fan “Auto” logic n 00070007Low profile design – less that 12” high n 0007Built-in condensate pump
A B SO L U T E C O MF O RT
6
n Indoor 00070007 Air Quality options include filters (MERV 8 and 13) and UV Air Cleaner Module n 00070007Service access from below
DAIKIN AC
FXMQ_P Specifications FXMQ_P Specifications
0.6-Ton
0.75-Ton
1-Ton
1.5-Ton
2-Ton
2.5-Ton
3-Ton
4-Ton
Model Name FXMQ07PVJU FXMQ09PVJU FXMQ12PVJU FXMQ18PVJU FXMQ24PVJU FXMQ30PVJU FXMQ36PVJU FXMQ48PVJU Power Supply V/ph/Hz 208-230/1/60 Cooling Capacity Btu/h 7,500 9,500 12,000 18,000 24,000 30,000 36,000 48,000 Heating Capacity Btu/h 8,500 10,500 13,500 20,000 27,000 34,000 40,000 54,000 Refrigerant R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A Refrigerant Control Electronic Expansion Valve Airflow Rate HH/H/L cfm 317/264/229 317/264/229 335/282/246 635/582/529 688/618/565 882/794/706 1,130/953/812 1,377/1,165/988 Unit Weight lbs. 55 55 55 80 80 80 102 102 Unit Height in. 11 13/16 11 13/16 11 13/16 11 13/16 11 13/16 11 13/16 11 13/16 11 13/16 Unit Width in. 21 5/8 21 5/8 21 5/8 39 3/8 39 3/8 39 3/8 55 1/8 55 1/8 Unit Depth in. 27 9/16 27 9/16 27 9/16 27 9/16 27 9/16 27 9/16 27 9/16 27 9/16 Sound Pressure H/L dB(A) 33/29 33/29 34/29 41/37 42/38 43/39 43/39 44/40 External Static Pressure in. W.G. 0.40/0.12 0.40/0.12 0.40/0.12 0.80/0.20 0.80/0.20 0.80/0.20 0.80/0.20 0.80/0.20 (High/Low) Unit Condensate in. O.D. 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 Connection Condensate Pump Lift in. 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 Liquid in. 1/4 Flare 1/4 Flare 1/4 Flare 1/4 Flare 3/8 Flare 3/8 Flare 3/8 Flare 3/8 Flare Pipe Connections Gas in. 1/2 Flare 1/2 Flare 1/2 Flare 1/2 Flare 5/8 Flare 5/8 Flare 5/8 Flare 5/8 Flare External Finish Galvanized Steel Plate Fuse Protection Devices Fan Driver Overload Protector Recommended Fuse/ A 15 15 15 15 15 15 15 15 Breaker Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
Note: Specifications are subject to change without notice.
FXMQ_P Accessories Model Name FXMQ07PVJU FXMQ09PVJU FXMQ12PVJU FXMQ18PVJU Navigation Remote Controller BRC1E71 BRC1E71 BRC1E71 BRC1E71 Simplified Wired Remote Controller* BRC2A71 BRC2A71 BRC2A71 BRC2A71 Wireless Remote Controller BRC4C82 BRC4C82 BRC4C82 BRC4C82 Remote Sensor Kit KRCS01-4B KRCS01-4B KRCS01-4B KRCS01-4B Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA KRP1B71 KRP1B71 KRP1B71 KRP1B71
FXMQ24PVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-4B
FXMQ30PVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-4B
FXMQ36PVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-4B
FXMQ48PVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-4B
KRP1B71
KRP1B71
KRP1B71
KRP1B71
KRP4A71
KRP4A71
KRP4A71
KRP4A71
damper/fan)
Group Control Adaptor PCB (connects to external BMS)
KRP4A71
KRP4A71
KRP4A71
KRP4A71
* Optional face plates available to provide a more intuitive user interface and disable specific functions
FXMQ_P Installation Space Air Inlet
a
a
Ceiling (length: in.)
18” or more
Ceiling Floor Surface
A B SO L UT E C OM F O RT
Air Outlet
Floor Surface
a = 12” or more if one inspection hatch (17“ 3/4 x 17” 3/4) on the control box side and a space of 11“ 13/16 or more under the unit. a = 1” or more if an inspection hatch the size of the indoor unit plus an additional 12” or more on the control box side is installed.
INDOOR w w w. d a i k i n a c . c o m
7
Concealed Ceiling Unit (medium static) FXMQ_MVJU Concealed. Slim design. Strong. Comfortable. The new FXMQ_MVJU ducted fan coil unit is ideal for larger open space floor plans usually found in offices, retails, hotels or education facilities. It is a perfect addition to Daikin’s line up of ducted units that performs well across multiple spaces that can benefit from the same mode of operation, limiting equipment and installation cost.
OSA
Outside air integration possible
Features and Benefits n G 0007 reater design flexibility with a capacity range extended
to 96 MBH n I0007mproved ductwork and filtration flexibility with high CFM
and ESP capabilities of up to 1.1” W.G. n L0007 ow profile design of less than 19” high to reduce required
installation space n B 0007 uilt-in condensate float switch (condensate pump is
not included)
A B SO L U T E C O MF O RT
8
DAIKIN AC
Application n n n n n
H 0007 otel/Conference centers S0007 chools R 0007 etail/Shopping centers L0007 arge open plan offices C 0007 hurches
FXMQ_M Specifications FXMQ_M Specifications Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L External Static Pressure (Nominal/Maximum) Unit Condensate Connection Liquid Pipe Connections Gas External Finish
6-Ton V/ph/Hz Btu/h Btu/h
cfm lbs. in. in. in. dB(A) in. W.G.
0.38/0.95
in. O.D. in. in.
1 1 3/8 Flare 3/8 Flare 3/4 Flare 7/8 Flare Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15 15
Protection Devices Recommended Fuse/Breaker
A
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
8-Ton
FXMQ72MVJU FXMQ96MVJU 208-230/1/60 72,000 96,000 81,000 108,000 R-410A R-410A Electronic Expansion Valve 2,047 / 1,764 2,541 / 2,188 302 302 18 1/8 18 1/8 54 3/8 54 3/8 43 5/16 43 5/16 48/45 48/45 0.43/0.95
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
Note: Specifications are subject to change without notice.
FXMQ_M Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor Kit Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB (connects to external BMS)
FXMQ72MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXMQ96MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
KRP1B71
KRP1B71
KRP4A71
KRP4A71
High Efficiency Filter Kit (MERV 13) DACA-MQ96M-13-1K DACA-MQ96M-13-1K High Efficiency Filter Kit (MERV 8) DACA-MQ96M-8-1K DACA-MQ96M-8-1K * Optional face plates available to provide a more intuitive user interface and disable specific functions
FXMQ_M Installation Space
Air Inlet
a
a
Ceiling (length: in.)
18” or more
Ceiling Floor Surface
A B SO L UT E C OM F O RT
Air Outlet
Floor Surface
a = 12” or more if one inspection hatch (17“ 3/4 x 17” 3/4) on the control box side and a space of 11“ 13/16 or more under the unit. a = 1” or more if an inspection hatch the size of the indoor unit plus an additional 12” or more on the control box side is installed.
INDOOR w w w. d a i k i n a c . c o m
9
Slim Duct Built-In Concealed Ceiling Unit FXDQ_MVJU Concealed. Slim. Quiet. Comfortable The slim duct built-in concealed unit is available for use with the VRV systems to complement the existing concealed ceiling unit options (FXMQ). With its low profile and low sound level this unit can be installed into limited ceiling void, bulkhead or soffit space.
Condensate pump as standard
OSA
Outside air integration possible
Filter included
Application n n n n n
H 0007 otel rooms M 0007 ulti-family residences S0007 ingle family residences S0007 chool dormitories R 0007 etail
Features and Benefits n S0007 lim height, at only 7 7/8”, makes it suitable for most of the applications where attic / bulkhead space is limited n W 0007 ith a sound level as low as 29 dB(A) for the 7.5, 9 or 12 MBH indoor unit, these units are among the quietest on the market n F0007 actory set rear suction; bottom suction is possible to reverse n Washable filter included n C 0007 ondensate pump with vertical lift of up to 21 5/8” included as standard n B 0007 lends unobtrusively with any interior decor; only the suction and discharge grills are visible n M 0007 edium static pressure facilitates unit use with flexible ducts of varying length
A B SO L U T E C O MF O RT
10
DAIKIN AC
FXDQ Specifications FXDQ Specifications Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L External Static Pressure (High/Low) Unit Condensate Connection Condensate Pump Lift Liquid Pipe Connections Gas External Finish
0.6-Ton
0.75-Ton
FXDQ07MVJU
FXDQ09MVJU
7,500 8,500 R-410A
9,500 10,500 R-410A
cfm lbs. in. in. in. dB(A)
280/226 51 7 7/8 27 9/16 24 7/16 33/29
280/226 51 7 7/8 27 9/16 24 7/16 33/29
in. W.G.
0.12/0.04
0.12/0.04
in. O.D. in. in. in.
1 1/32 21 5/8 1/4 Flare 1/2 Flare
1 1/32 21 5/8 1/4 Flare 1/2 Flare
A
15
15
V/ph/Hz Btu/h Btu/h
Protection Devices Recommended Fuse/Breaker Standard Filter Type
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
1-Ton
1.5-Ton
2-Ton
FXDQ12MVJU FXDQ18MVJU 208-230/1/60 12,000 18,000 13,500 20,000 R-410A R-410A Electronic Expansion Valve 280/226 440/350 51 63 7 7/8 7 7/8 27 9/16 35 7/16 24 7/16 24 7/16 33/29 35/31 0.12/0.04
FXDQ24MVJU 24,000 27,000 R-410A 580/460 71 7 7/8 43 5/16 24 7/16 36/32
0.17/0.06
0.17/0.06
1 1/32 1 1/32 21 5/8 21 5/8 1/4 Flare 1/4 Flare 1/2 Flare 1/2 Flare Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15 15 Removable, Washable, Mildew Proof
1 1/32 21 5/8 3/8 Flare 5/8 Flare
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
15
Note: Specifications are subject to change without notice.
FXDQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor Kit Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB (connects to external BMS)
FXDQ07MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXDQ09MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXDQ12MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXDQ18MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXDQ24MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
KRP1B71-D
KRP1B71-D
KRP1B71-D
KRP1B71-D
KRP1B71-D
KRP4A74
KRP4A74
KRP4A74
KRP4A74
KRP4A74
APFXDQ18 APRFFXDQ18 APRFFXDQ18F
APFXDQ24 APRFFXDQ24 APRFFXDQ24F
APFXDQ070912 APFXDQ070912 APFXDQ070912 Access Panel (single door) APRFFXDQ070912 APRFFXDQ070912 APRFFXDQ070912 Access Panel with return air filter (single door) APRFFXDQ070912F APRFFXDQ070912F APRFFXDQ070912F Filter Media Replacement * Optional face plates available to provide a more intuitive user interface and disable specific functions
FXDQ Installation Space Choose an installation site that ensures both optimum air distribution and sufficient clearance for maintenance.
The return air inlet can be easily changed from rear to bottom using the same chamber lid.
Protection net Air inlet 12” or more
Control Box
Maintenance Space
Chamber lid
13/16” or more
Celing
H= 9-1/2”or more
7-7/8”
Chamber lid Air discharge
Floor surface (length : in.)
Protection net Air discharge
A B SO L UT E C OM F O RT
Maintenance Space
100”or more
12” or more
INDOOR Air inlet
w w w. d a i k i n a c . c o m
11
Round Flow Ceiling-Mounted Cassette FXFQ_PVJU
For use with:
Quiet. Elegant. Customizable. Low-maintenance. Comfortable. The Round Flow cassette is ideal for open plan applications such as classrooms and offices where variances in temperature and airflow can cause discomfort. With 23 configurable airflow distribution patterns, it can also be effective in smaller, more intricate spaces too. Condensate pump as standard
OSA
Outside air integration possible
Filter included
Features and Benefits n 360° airflow to reduce drafts and improve comfort n M 0007 odels range from 9 MBH to 48 MBH n I0007mproved flexibility with 23 different possible airflow patterns, ensuring ideal air distribution to maximize comfort and savings n Lower air velocities for better room airflow distribution n R 0007 educed unit weight and improved efficiency with a light weight fan n Stain resistant and easily cleanable decoration panel coating n Silver ion antibacterial drain pan treatment n 3 user selectable fan speeds (HH, H and L)
Airflow directions For air discharge in 2 or 3 directions, it is necessary to make field settings by remote controller and to close the air outlet(s). Refer to the section FIELD SETTING in the installation manual of the optional blocking pad kit.
A B SO L U T E C O MF O RT
Example of airflow patterns 12
DAIKIN AC
Application n n n n
R 0007 etail S0007 chools O 0007 ffices R 0007 estaurants
FXFQ Specifications FXFQ Specifications
0.75-Ton
1-Ton
1.5-Ton
Model Name Power Supply Rated Cooling Capacity Rated Heating Capacity Refrigerant Refrigerant Control Airflow Rate HH/H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure HH/H/L Unit Condensate Connection Condensate Pump Lift Gas Pipe Connections Liquid External Finish
FXFQ09PVJU
FXFQ12PVJU
FXFQ18PVJU
V/ph/Hz Btu/h Btu/h
9,500 10,500
12,000 13,500
cfm lbs. in. in. in. dB(A) in. O.D. in. in. in.
460/390/350 43 9 11/16 33 1/16 33 1/16 30/28/27 1 1/4 33 1/2 1/4 (Flare) 1/2 (Flare)
460/390/350 43 9 11/16 33 1/16 33 1/16 30/28/27 1 1/4 33 1/2 1/4 (Flare) 1/2 (Flare)
A
15
15
Protection Devices Recommended Fuse/Breaker Standard Filter Type
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
2-Ton
2.5-Ton
FXFQ24PVJU FXFQ30PVJU 208-230/1/60 18,000 24,000 30,000 20,000 27,000 34,000 R-410A Electronic Expansion Valve 560/470/390 780/620/470 830/670/530 43 48.5 48.5 9 11/16 9 11/16 9 11/16 33 1/16 33 1/16 33 1/16 33 1/16 33 1/16 33 1/16 32/30/27 36/32/28 38/35/31 1 1/4 1 1/4 1 1/4 33 1/2 33 1/2 33 1/2 1/4 (Flare) 3/8 (Flare) 3/8 (Flare) 1/2 (Flare) 5/8(Flare) 5/8(Flare) Galvanized Steel Plate Fuse/Breaker Fan Motor Thermal Protector 15 15 15 Mold Resistant Resin Net
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
3-Ton
4-Ton
FXFQ36PVJU
FXFQ48PVJU
36,000 40,000
48,000 54,000
1,180/910/700 1,220/970/790 55 55 11 5/16 11 5/16 33 1/16 33 1/16 33 1/16 33 1/16 44/38/32 45/40/34 1 1/4 1 1/4 33 1/2 33 1/2 3/8 (Flare) 3/8 (Flare) 5/8(Flare) 5/8(Flare)
15
15
Note: Specifications are subject to change without notice.
FXFQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor Kit Decoration Panel Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB (connects to external BMS)
FXFQ09PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
FXFQ12PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
FXFQ18PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
FXFQ24PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
FXFQ30PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
FXFQ36PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
FXFQ48PVJU BRC1E71 BRC2A71 BRC7F812 KRCS01-4B BYCP125K-W1
KRP1C75
KRP1C75
KRP1C75
KRP1C75
KRP1C75
KRP1C75
KRP1C75
KRP4A74
KRP4A74
KRP4A74
KRP4A74
Long-Life Replacement Filter KAFP551K160 KAFP551K160 KAFP551K160 KAFP551K160 Panel Spacer KDBP55H160FA KDBP55H160FA KDBP55H160FA KDBP55H160FA Fresh Air Intake Kit with T pipe KDDP55B160K KDDP55B160K KDDP55B160K KDDP55B160K Fresh Air Intake Kit without T pipe KDDP55B160 KDDP55B160 KDDP55B160 KDDP55B160 * Optional face plates available to provide a more intuitive user interface and disable specific functions
KRP4A74
KRP4A74
KRP4A74
KAFP551K160 KDBP55H160FA KDDP55B160K KDDP55B160
KAFP551K160 KDBP55H160FA KDDP55B160K KDDP55B160
KAFP551K160 KDBP55H160FA KDDP55B160K KDDP55B160
FXFQ Installation Space
*60” or more
Air discharge
Air inlet
Air discharge *60” or more
H
Air inlet *60” or more Air discharge Air discharge *60” or more
Floor Surface (NOTE) Leave 7 7/8” or more space where marked with the *, on sides where the air outlet is closed.
At least 70” from the floor
H 10” 11 3/4” or more
A B SO L UT E C OM F O RT
H
Model FXFQ09 • 12 • 18 • 24 • 30PVJU FXFQ36 • 48PVJU
INDOOR w w w. d a i k i n a c . c o m
13
2’ x 2’ 4-way Ceiling-mounted cassette FXZQ_M7VJU Soft. Elegant. Customizable. Low-maintenance. Comfortable. From corner stores to offices and classrooms, our elegant ceilingmounted cassette units provide low-noise, customizable comfort. Airflow can be sent in any of four directions, and the ability to shut down one or two sides allows for easy corner installation. For easier installation, units fit in a standard 2’ x 2’ ceiling grid.
Condensate pump as standard
OSA
Outside air integration possible
Filter included
Features and Benefits Application n R 0007 etail n S 0007 chools n O 0007 ffices
n Sound pressure levels are as low as 29 dB(A) n 0007Space-saving depth of units requires only 11.6” of ceiling space n T0007 hree auto-swing positions to choose from – standard, draft prevention and ceiling stain prevention n S0007 imple installation with an easy-to-fit decoration panel, easy height adjustment and a suction grille that can rotate up to 90° n E0007 asy-to-clean grille, washable long-life filter and optional high efficiency filters n Trouble-free condensate pump inside the unit n 0007Models range from 7.5 MBH to 18 MBH
Airflow directions For air discharge in 2 or 3 directions, it is necessary to make field settings by remote controller and to close the air outlet(s). Refer to the section FIELD SETTING in the installation manual of the optional blocking pad kit.
A B SO L U T E C O MF O RT
Example of airflow patterns 14
DAIKIN AC
FXZQ Specifications FXZQ Specifications
0.6-Ton
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Condensate Pump Lift Liquid Pipe Connections Gas External Finish
FXZQ07M7VJU V/ph/Hz Btu/h Btu/h
7,500 8,700 R-410A
cfm lbs. in. in. in. dB(A) in. O.D. in. in. in.
320/247 42 11 1/4 22 5/8 22 5/8 31/29 1 1/32 21 1/2 1/4 Flare 1/2 Flare
A
15
Protection Devices Recommended Fuse/Breaker Standard Filter Type
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
0.75-Ton
1-Ton
FXZQ09M7VJU FXZQ12M7VJU 208-230/1/60 9,500 12,000 11,100 14,000 R-410A R-410A Electronic Expansion Valve 335/265 495/353 42 42 11 1/4 11 1/4 22 5/8 22 5/8 22 5/8 22 5/8 33/29 41/34 1 1/32 1 1/32 21 1/2 21 1/2 1/4 Flare 1/4 Flare 1/2 Flare 1/2 Flare Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15 15 Resin Net (with Mold Resistant)
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
1.5-Ton FXZQ18M7VJU 18,000 21,000 R-410A 495/353 42 11 1/4 22 5/8 22 5/8 41/34 1 1/32 21 1/2 1/4 Flare 1/2 Flare
15
Note: Specifications are subject to change without notice.
FXZQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Remote Sensor Kit Decoration Panel Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
FXZQ07M7VJU BRC1E71 BRC2A71 KRCS01-1B BYFQ60BU
FXZQ09M7VJU BRC1E71 BRC2A71 KRCS01-1B BYFQ60BU
FXZQ12M7VJU BRC1E71 BRC2A71 KRCS01-1B BYFQ60BU
FXZQ18M7VJU BRC1E71 BRC2A71 KRCS01-1B BYFQ60BU
KRP1B72
KRP1B72
KRP1B72
KRP1B72
KAFQ441B60 KDBHQ44B60 KDBQ44B60 KDDQ44XA60
KAFQ441B60 KDBHQ44B60 KDBQ44B60 KDDQ44XA60
Long-Life Replacement Filter KAFQ441B60 KAFQ441B60 Sealing Member of Air Discharge Outlet KDBHQ44B60 KDBHQ44B60 Panel Spacer KDBQ44B60 KDBQ44B60 Fresh Air Intake Kit KDDQ44XA60 KDDQ44XA60 * Optional face plates available to provide a more intuitive user interface and disable specific functions
FXZQ Installation Space
H
Air discharge
Air inlet
Air discharge *59 or more
H 11.6 or more (length: in.)
Air inlet *59 or more Air discharge Air discharge *59 or more A B SO L UT E C OM F O RT
*59 or more
H
Model FXZQ07-18M7VJU
(NOTE) Leave 7 7/8 or more space where marked with the *, on sides where the air outlet is closed.
INDOOR w w w. d a i k i n a c . c o m
15
Wall-mounted Unit FXAQ_MVJU
Stylish. Compact. Convenient. Comfortable. Our wall-mounted units are ideal for cooling or heating smaller zones such as hotel rooms, stores, small offices and restaurants. The compact, stylish design lets the unit blend discreetly into any interior design, and airflow can be sent in any of five different directions and programmed via remote control.
Filter included
Features and Benefits n A 0007 uto-swing mechanism ensures efficient air distribution via louvers that automatically close when the unit is turned off n Wide 00070007 air discharge outlet distributes a comfortable airflow throughout the entire space n Horizontal 00070007 louvers and front panel can be easily removed for cleaning n 0007Drain pipe can be easily hidden from sight n 0007Models range from 7.5 MBH to 24 MBH
A B SO L U T E C O MF O RT
16
DAIKIN AC
Application n n n n n
R 0007 etail R 0007 estaurants O 0007 ffices H 0007 otels M 0007 ulti-family residences
FXAQ Specifications FXAQ Specifications Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Liquid Pipe Connections Gas External Finish
0.6-Ton
0.75-Ton
FXAQ07MVJU
FXAQ09MVJU
7,500 8,500 R-410A
9,500 10,500 R-410A
cfm lbs. in. in. in. dB(A) in. O.D. in. in.
260/160 25 11 3/8 31 1/4 9 36/31 11/16 1/4 1/2
280/175 25 11 3/8 31 1/4 9 37/31 11/16 1/4 1/2
A
15
15
V/ph/Hz Btu/h Btu/h
Protection Devices Recommended Fuse/Breaker Standard Filter Type
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
1-Ton
1.5-Ton
2-Ton
FXAQ12MVJU FXAQ18MVJU 208-230/1/60 12,000 18,000 13,500 20,000 R-410A R-410A Electronic Expansion Valve 300/180 500/400 25 31 11 3/8 11 3/8 31 1/4 41 3/8 9 9 38/31 43/37 11/16 11/16 1/4 1/4 1/2 1/2 White Casing Fuse Fan Motor Thermal Protector 15 15 Resin Net (washable)
FXAQ24MVJU 24,000 27,000 R-410A 635/470 31 11 3/8 41 3/8 9 47/40 11/16 3/8 5/8
15
Note: Specifications are subject to change without notice.
FXAQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor Kit Group Control Adaptor PCB (connects to external BMS)
FXAQ07MVJU BRC1E71 BRC2A71 BRC7E818 KRCS01-1B
FXAQ09MVJU BRC1E71 BRC2A71 BRC7E818 KRCS01-1B
FXAQ12MVJU BRC1E71 BRC2A71 BRC7E818 KRCS01-1B
FXAQ18MVJU BRC1E71 BRC2A71 BRC7E818 KRCS01-1B
FXAQ24MVJU BRC1E71 BRC2A71 BRC7E818 KRCS01-1B
KRP4A71
KRP4A71
KRP4A71
KRP4A71
KRP4A71
DACA-CP1-1
DACA-CP1-1
Condensate Pump DACA-CP1-1 DACA-CP1-1 DACA-CP1-1 * Optional face plates available to provide a more intuitive user interface and disable specific functions
FXAQ Installation Space [ Space required for installaion (in.) ] ≥2
≥2
≥ 3 1/2
Installation panel (1)
Fig.1
Left pipe
Obstruction ≤ 4 3/4
≥ 100 (from floor) For installation in high places.
Back-left pipe Bottom-left pipe Back-right pipe
Floor Fig. 2
Fig.3
Bottom-right pipe
A B SO L UT E C OM F O RT
≥ 1 1/4
Temporary screw (In case of 12 type)
INDOOR w w w. d a i k i n a c . c o m
17
Ceiling Suspended Unit FXHQ_MVJU Slim. Efficient. Quiet. Easy to Maintain. With its slim, elegant design, the FXHQ ceiling-suspended unit is a great fit for any light commercial space. Wide air openings provide a comfortable airflow and an innovative stream fan ensures quiet operation, making it ideal for retail stores, restaurants, classrooms and conference rooms.
Filter included
Application n R 0007 etail/Shops n O 0007 ffices n R 0007 estaurants
Features and Benefits n O 0007 ne of our slimmest indoor units (less than 8”) fits within any interior design n W 0007 ide air discharge outlet distributes a comfortable airflow throughout the entire space n 00070007Innovative stream fan technology keeps sound pressure levels low n 00070007Installation is fast and optional drain-up kit can be added easily n 0007Bristle-free, non-dew flap and flat design make cleaning simple n 0007Long-life filter (maintenance-free for up to one year) is standard n 0007Models range from 12 MBH to 36 MBH
A B SO L U T E C O MF O RT
18
DAIKIN AC
FXHQ Specifications FXHQ Specifications
1-Ton
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Liquid Pipe Connections Gas External Finish
V/ph/Hz Btu/h Btu/h
cfm lbs. in. in. in. dB(A) in. O.D. in. in.
Protection Devices Recommended Fuse/Breaker Standard Filter Type Nominal Conditions:
2-Ton
3-Ton
FXHQ12MVJU
A
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
FXHQ24MVJU FXHQ36MVJU 208-230/1/60 12,000 24,000 36,000 13,500 27,000 40,000 R-410A R-410A R-410A Electronic Expansion Valve 410/340 710/600 830/670 55 80 90 7 11/16 7 11/16 7 11/16 37 13/16 55 1/8 62 5/8 26 3/4 26 3/4 26 3/4 42/33 44/36 46/41 1 1 1 1/4 3/8 3/8 1/2 5/8 5/8 White Casing Fuse Fan Motor Thermal Protector 15 15 15 Resin Net (with Mold Resistant)
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
Note: Specifications are subject to change without notice.
FXHQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor Kit Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB (connects to external BMS)
FXHQ12MVJU BRC1E71 BRC2A71 BRC7E83 KRCS01-1B
FXHQ24MVJU BRC1E71 BRC2A71 BRC7E83 KRCS01-1B
FXHQ36MVJU BRC1E71 BRC2A71 BRC7E83 KRCS01-1B
KRP1B71
KRP1B71
KRP1B71
KRP4A72
KRP4A72
KRP4A72
Replacement long-life filter KAFJ501D56 KAFJ501D112 KAFJ501D160 L-type piping kit KHFP5M35 KHFP5M63 KHFP5M160 * Optional face plates available to provide a more intuitive user interface and disable specific functions
FXHQ Installation Space
1 3/16 or more
Air outlet Required service space
Air inlet
1 3/16 or more
12 or more
A B SO L UT E C OM F O RT
Obstruction Floor
INDOOR w w w. d a i k i n a c . c o m
19
Floor-Standing Units FXLQ_MVJU/FXNQ_MVJU
Versatile. Logical. Durable. Quiet. The ideal way to save space, our floor-standing units can easily be installed along a perimeter wall – or concealed. The air distribution from these models will allow you to find the right balance for classrooms, hospital rooms, office hallways or similar spaces.
OSA
Outside air integration possible (FXNQ) Filter included
FXLQ FXNQ
Features and Benefits n 00070007Ideal for installation beneath a window n 0007Unit requires minimal installation space n 00070007Fitted with a washable long-life filter n 0007Remote-control options available n S0007 pace-saving unit can be freestanding or wall-mounted, concealed or exposed n 0007Models range from 12 MBH to 24 MBH
A B SO L U T E C O MF O RT
20
DAIKIN AC
Application n n n n n n
M 0007 ulti-family residences S0007 ingle family residences C 0007 hurches H 0007 istoric buildings S0007 chools O 0007 ffices
FXLQ/FXNQ Specifications FXLQ/FXNQ Specifications Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Liquid Pipe Connections Gas External Finish
2-Ton
FXLQ18MVJU FXLQ24MVJU 208-230/1/60 12,000 18,000 24,000 13,500 20,000 27,000 R-410A R-410A R-410A Electronic Expansion Valve 280/210 490/380 560/420 66 80 80 23 5/8 23 5/8 23 5/8 44 7/8 55 7/8 55 7/8 8 3/4 8 3/4 8 3/4 36/33 40/35 41/36 27/32 27/32 27/32 1/4 1/4 3/8 1/2 1/2 5/8 Ivory White Casing Fuse Fan Motor Thermal Protector 15 15 15 Resin Net (with Mold Resistant)
V/ph/Hz Btu/h Btu/h
cfm lbs. in. in. in. dB(A) in. O.D. in. in.
Recommended Fuse/Breaker Standard Filter Type
A
Cooling Mode Indoor: 80 °F DB / 67 °F WB Outdoor: 95 °F DB Pipe Length: 25 ft. Level Difference: 0 ft.
Concealed 1.5-Ton
1-Ton
FXLQ12MVJU
Protection Devices
Nominal Conditions:
Exposed 1.5-Ton
1-Ton
2-Ton
FXNQ12MVJU
FXNQ18MVJU FXNQ24MVJU 208-230/1/60 12,000 18,000 24,000 13,500 20,000 27,000 R-410A R-410A R-410A Electronic Expansion Valve 280/210 490/380 560/420 51 60 60 24 24 24 42 1/8 53 1/8 53 1/8 8 5/8 8 5/8 8 5/8 36/33 40/35 41/36 27/32 27/32 27/32 1/4 1/4 3/8 1/2 1/2 5/8 Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15 15 15 Resin Net (with Mold Resistant)
Heating Mode Indoor: 70 °F DB Outdoor: 47 °F DB / 43 °F WB Pipe Length: 25 ft. Level Difference: 0 ft.
Note: Specifications are subject to change without notice.
FXLQ/FXNQ Accessories Model Name Navigation Remote Controller Simplified Wired Remote Controller* Wireless Remote Controller Remote Sensor Kit Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB (connects to external BMS)
FXLQ12MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXLQ18MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXLQ24MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXNQ12MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXNQ18MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
FXNQ24MVJU BRC1E71 BRC2A71 BRC4C82 KRCS01-1B
KRP1B71
KRP1B71
KRP1B71
KRP1B71
KRP1B71
KRP1B71
KRP4A71
KRP4A71
KRP4A71
KRP4A71
KRP4A71
KRP4A71
* Optional face plates available to provide a more intuitive user interface and disable specific functions
FXLQ/FXNQ Installation Space FXNQ
FXLQ
24 5/8 3 1/8 or more
Window
Maintenance area
A
or
Front side 4 or more (FXLQ) 40 or more
6 or more (FXNQ)
(IMPORTANT) Leave sufficient clearance for air inlet and maintenance. Model
Air inlet direction Base (length: in.)
A (in.)
B (in.)
FXNQ12MVJU
28
46
FXNQ18 · 24MVJU
39
57
A B SO L UT E C OM F O RT
3/4 or more
(length: in.) Air flow direction 70 or more
4 or more (FXLQ)
m
o r m re or e
Bo
INDOOR w w w. d a i k i n a c . c o m
21
100% Outside Air Processing Unit FXMQ_MFVJU Concealed. Powerful. Compact. Quiet. Fresh Air Quality. Both fresh air treatment and heating and cooling can be achieved successfully in a single system via heat pump technology without the usual design problems associated with balancing air supply and discharge. Fan coil units and outdoor air processing unit can be connected to the same refrigerant line, resulting in enhanced design flexibility and a significant reduction in total system costs.
Operational Characteristics
Features and Benefits
When the suction air temperature is between 66°F and 109°F the Outside Air Processing Unit operates in cooling, and when between 23°F and 59°F, it operates in heating. The OA processing unit will work in energy saving fan only between 59°F and 66°F; this is not configurable.
n C 0007 an be connected to all North American Daikin VRV systems
66°F
23°F
n A 0007 vailable in three capacities, nominal 48, 72 and 96 MBH n T0007 he nominal airflow are 635, 988, and 1,236 CFM respectively
109°F
n I0007ndoor Air Quality options include MERV 8 and 13 filters and filter boxes
Heating A B SO L U T E C O MF O RT
22
n C 0007 onnects directly and seamlessly into the Daikin local and centralized control suite
Fan only operation
Operation limit (heating)
23
32
DAIKIN AC
43
Cooling 59
n T0007 he indoor unit is controlled to a set cooling and heating discharge air temperature allowing the flexibility to integrate with a standard Daikin indoor unit or duct directly to the space n A 0007 low profile design of only 18.5” high reduces the required installation space and can eliminate mechanical rooms or additional structural supports associated with traditional OA systems
Operation limit (cooling)
59°F
n E0007 xternal static pressure capabilities of up to 1.03” W.G. allows for flexibility with duct work and filtration choices
66
64
92
107 109
FXMQ_MFVJU Specifications FXMQ_MFVJU Specifications V/ph/Hz Btu/h Btu/h cfm lbs. in. in. in. dB(A) in. W.G. in. in.
Liquid Gas
Pipe Connections
4-Ton FXMQ48MFVJU
Model Name Power Supply Cooling Capacity Heating Capacity Airflow Rate Unit Weight Unit Height Unit Width Unit Depth Sound Pressure External Static Pressure
48,000 30,000 635 190 18 1/2 29 1/4 43 5/16 42 0.88 3/8 5/8
External Finish Protection Devices Operating Range - Cooling Operating Range - Heating Discharge Air Temp. - Cooling Discharge Air Temp. - Heating
°F °F °F °F
Cooling Mode Discharge Set Temperature: 64 °F DB Outdoor: 91 °F DB, 82 °F WB (68% RH) Pipe Length: 25 ft. Level Difference: 0 ft.
Nominal Conditions:
6-Ton
8-Ton
FXMQ72MFVJU FXMQ96MFVJU 208-230/1/60 72,000 96,000 47,000 59,000 988 1,236 271 271 18 1/2 18 1/2 54 3/8 54 3/8 43 5/16 43 5/16 47 47 0.96 1.03 3/8 3/8 3/4 7/8 Galvanized Steel Plate Fuse Fan Motor Thermal Protector 66 DB/59 WB - 95 DB/90 WB 23 DB to 68 DB 55 - 77 64 - 86
Heating Mode Discharge Set Temperature: 77 °F DB Outdoor: 32 °F DB, 27 °F WB (50% RH) Pipe Length: 25 ft. Level Difference: 0 ft.
Connection Rules n W 0007 hen the Outside Air Processing Unit (OA processing unit) is used in conjunction with standard indoor unit(s) on a single piping network, the total combined connected capacity ratio of standard indoor unit(s) and OA processing unit must be equal or within 50% and 100% of the capacity of the condensing unit. In addition, the connected capacity of the OA processing unit must be equal or less than 30% of the capacity of the condensing unit. n W 0007 hen the condensing unit is dedicated to the OA processing unit, the connected capacity of the OA processing unit must be equal or within 50% to 100% of the capacity of the condensing unit.
Note: Specifications are subject to change without notice.
FXMQ_MFVJU Accessories Model Name Navigation Remote Controller Wireless Remote Controller Remote Sensor Kit Wiring Adaptor PCB (interface with aux/primary heater, humidifier, OA damper/fan)
Group Control Adaptor PCB (connects to external BMS)
High Efficiency Filter Kit (MERV 13) High Efficiency Filter Kit (MERV 8)
FXMQ48MFVJU BRC1E71 BRC4C82 KRCS01-1B
FXMQ72MFVJU BRC1E71 BRC4C82 KRCS01-1B
FXMQ96MFVJU BRC1E71 BRC4C82 KRCS01-1B
KRP1B71
KRP1B71
KRP1B71
KRP4A71
KRP4A71
KRP4A71
DACA-MQ48F-13-1K DACA-MQ96F-13-1K DACA-MQ96F-13-1K DACA-MQ48F-8-1K DACA-MQ96F-8-1K DACA-MQ96F-8-1K
FXMQ_MFVJU Layout Example VRVIII Series Outdoor Units
Indoor Unit
Indoor Unit
Outdoor Air processing unit
Outside air supply
Air-conditioning
Discharge Side
Suction Side
2.5” or more
(length: in.)
A B SO L UT E C OM F O RT
FXMQ_MFVJU Installation Space
Ceiling
2.5” or more
25 9/16” or more Ceiling
INDOOR w w w. d a i k i n a c . c o m
23
WARNINGS: • 0007Always use a licensed installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. • 0007Use only those parts and accessories supplied or specified by Daikin. Ask a licensed contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. • 0007Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. For any inquiries, contact your local Daikin sales office.
© 2011 Daikin Industries, Limited. Daikin , Daikin AC Absolute Comfort, and its design, VRV and REFNET ™ are trademarks pending or registered trademarks of Daikin Industries, Limited. All rights reserved. LonWorks and LON are registered trademarks of Echelon Corporation. BACnet is a Data Communication Protocol for Building Automation and Control Networks, developed under the auspices of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). ®
®
®
®
®
®
Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION
JMI-0107
Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, COMMERCIAL HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, MARINE TYPE CONTAINER REFRIGERATION UNITS, COMPRESSORS AND VALVES.
Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM.
All of the Daikin Group's business facilities and subsidiaries in Japan are certified under the ISO 14001 International standard for environmental management.
JQA-1452
Daikin AC (Americas), Inc.
Dealer Information
PCVINDUSE11-02C
Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations. w w w. d a i k i n a c . c o m
A B SO L UT E C OM F O RT
1645 Wallace Drive, Suite 110 Carrollton, TX 75006 USA www.daikinac.com [email protected] 866-4DAIKIN 972-245-1510
24
Does anybody have a link to a pdf or something to tell me how to lock and unlock the controllers screen on a BRC1E71 controller. I found nothing in itds manual or online. I know how to do it but I want something I can give to other HVAC employees that I work with.
Showing slide {CURRENT_SLIDE} of {TOTAL_SLIDES} - Best Selling
- DAIKIN DZK ZONING KIT COLOR TOUCH THERMOSTAT DZK-MTS-2 AIRZONE AZDZKMTS2W
- Daikin BRC1D71 Wall Mounted Wired 7 Day Programmable Individual Controller
- (2)Total Ratings 2,
![Itm Itm](https://img.yumpu.com/29966173/1/500x640/dcs601c71-operation-manual-daikin-ac.jpg)
Lot of 4 Daikin High Resolution Touchscreen Digital Thermostat DT4272C
Condition: New. We are not an authorized dealer of this product and any warranty included with the product may not be honored by the manufacturer.0 bids$29.92 shippingEnding Oct 1 at 5:55AM PDT3d 12hBrand: DaikinCustoms services and international tracking providedDAIKIN D4272C 7 Day Programmable Commercial Digital Thermostat - New
Item Is New Never Installed.Brand: Daikin$24.00 shippingFeatures: Digital DisplayColor: WhiteDaikin 910121748 Programmable Electronic Thermostat NEW
Part Number: 910121748. Condition: NEW, opened for pictures. I do show the label when available so you can see the part number.Brand: DaikinWas: Previous Price$35.99Features: Digital DisplayColor: Whiteor Best OfferDAIKIN DZK ZONING KIT COLOR TOUCH THERMOSTAT DZK-MTS-2 AIRZONE AZDZKMTS2W NEW
Brand: Daikin$13.72 shippingCustoms services and international tracking providedDaikin, BRC1D71, Programmable Remote Controller
P/N BRC1D71.Top Rated Plus$24.00 shippingBrand: DaikinColor: WhiteDaikin Touchscreen Thermostat 4 Heat/2 Cool DT4272C High Resolution Wi-Fi
This is capable of 4 heat & 2 cool. Wi-Fi capable.Brand: Daikin$15.41 shippingFeatures: Digital DisplayColor: WhiteCustoms services and international tracking providedDaikin Programmable Touchscreen Thermostat 910121750
Brand: Daikin$14.90 shippingCustoms services and international tracking providedDaikin Replacement Wireless Remote Control ARC 452A19
Brand: Daikin$21.17 shippingCustoms services and international tracking provided048164100 Thermostat Mcquay
Brand: Daikin$15.13 shippingCustoms services and international tracking providedDaikin 668811101 ICM AS7848 Programmable Thermostat
We will then give you instructions on how to proceed.Brand: Daikin$16.44 shippingCustoms services and international tracking providedDaikin Replacement Wireless Remote Control ARC 452A20
ARC 452A20.Brand: Daikin$16.25 shippingDaikin Remote Control ARC 452A19 and filters
Brand: Daikin$17.14 shippingCustoms services and international tracking providedBenefits charityDaikin BRC1D71 Wall Mounted Wired 7 Day Programmable Individual Controller
New Daikin BRC1D71 Wall Mounted Wired 7 Day Programmable Individual Controller. Condition is New.Brand: Daikin$20.14 shippingColor: BeigeCustoms services and international tracking providedOEM/Authentic Daikin A/C Remote Control ARC452A19
OEM/Authentic Daikin A/C Remote Control ARC452A19. Condition is New. Shipped with USPS First Class Package.Brand: Daikin$14.25 shippingDaikin A/C Remote Control ARC480A1 works w/A2,A3,A6,A8 SPANISH Language Buttons
DAIKIN ARC48A01 Remote.Brand: Daikin$14.25 shippingDaikin Touchscreen Thermostat 2 Heat/3 Cool LAPP087 Touchscreen 910193127
Brand: Daikin$17.52 shippingColor: WhiteCustoms services and international tracking providedDAIKIN ONE PLUS Smart Thermostat
<p>DAIKIN ONE+ Smart Thermostat. Condition is New. Shipped with USPS Priority Mail.</p><p>Brand new </p><br><p>The Daikin One+ smart thermostat is an intelligent home air controller from one of the world’s leading heating, ventilating, and air conditioning (HVAC) manufacturers. It is the cloud-connected hub of a sophisticated, integrated solution for controlling temperature, humidity, and air quality.</p><br><p>Daikin Comfort Control App Daikin Comfort Control App </p><br><p>Compatible Equipment</p><p>AIR CONDITIONERS DX20VC, DX18TC, DX16TC, Daikin Fit (DX17VSS)</p><p>HEAT PUMPS DZ20VC, DZ18VC, DZ18TC, DZ16TC</p><p>GAS FURNACES DM97MC, DC97MC, DM96VC, DM80VC, DC80VC</p><p>AIR HANDLERS DVPEC, DVPTC, MBVC</p><br><p>Please double check before buying.</p>Brand: DaikinShowing slide {CURRENT_SLIDE} of {TOTAL_SLIDES} - Sponsored ListingsGot one to sell?
Get it in front of 160+ million buyers.
Showing slide {CURRENT_SLIDE} of {TOTAL_SLIDES} - Make an Offer
- Daikin 910121748 Programmable Electronic Thermostat NEW+$26.00 shippingMake Offer - Daikin 910121748 Programmable Electronic Thermostat NEW
- DAIKIN DZK ZONING KIT COLOR TOUCH THERMOSTAT DZK-MTS-2 AIRZONE AZDZKMTS2W NEW+$13.72 shippingMake Offer - DAIKIN DZK ZONING KIT COLOR TOUCH THERMOSTAT DZK-MTS-2 AIRZONE AZDZKMTS2W NEW
- Daikin Touchscreen Thermostat 4 Heat/2 Cool DT4272C High Resolution Wi-Fi+$15.41 shippingMake Offer - Daikin Touchscreen Thermostat 4 Heat/2 Cool DT4272C High Resolution Wi-Fi
- Daikin 668811101 ICM AS7848 Programmable Thermostat+$16.44 shippingMake Offer - Daikin 668811101 ICM AS7848 Programmable Thermostat
- $35.00Make Offer - Daikin Remote Control ARC 452A19 and filters
- Daikin BRC1D71 Wall Mounted Wired 7 Day Programmable Individual Controller+$20.14 shippingMake Offer - Daikin BRC1D71 Wall Mounted Wired 7 Day Programmable Individual Controller
- Daikin Touchscreen Thermostat 2 Heat/3 Cool LAPP087 Touchscreen 910193127+$17.52 shippingMake Offer - Daikin Touchscreen Thermostat 2 Heat/3 Cool LAPP087 Touchscreen 910193127
- $149.99Make Offer - DAIKIN DT4272C COMMERCIAL TOUCHSCREEN THERMOSTAT
- $89.99Make Offer - DAIKIN D4271C DIGITAL COMMERCIAL THERMOSTAT
- $100.00